A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ion Mobility Spectrometry and Tandem Mass Spectrometry Analysis of Estradiol Glucuronide Isomers. | LitMetric

Ion Mobility Spectrometry and Tandem Mass Spectrometry Analysis of Estradiol Glucuronide Isomers.

J Am Soc Mass Spectrom

Department of Chemistry, University of Nebraska - Lincoln, 711 Hamilton Hall, Lincoln, NE, 68588-0304, USA.

Published: October 2019

Estradiol is an estrogenic steroid that can undergo glucuronidation at two different sites, which results in two estradiol glucuronide regioisomers. These isomers can be produced by different enzymes and can have different biological activities before being eliminated from the body. Although there have been previous methods that can distinguish the two isomers, these methods often have long acquisition times or high cost per analysis. In this study, traveling wave ion mobility spectrometry (TWIMS) coupled with mass spectrometry (MS) was employed to separate estradiol glucuronides using alkali metal adduction in positive ion mode, where the sodiated dimer adduct provided adequate separation both in single-component standards and in two-component mixtures. Additionally, in negative ion mode, tandem mass spectrometry (MS/MS) was used to quantitatively determine the relative composition of the two isomers. This was possible due to differences in the energetic requirements for loss of the glucuronic acid, which was characterized by energy-resolved collision-induced dissociation (CID). This work demonstrated that the intensity of the glucuronic acid neutral loss product as compared with the intensity of the intact precursor ion can be used to determine the percentage of each isomer present in a mixture. Overall, TWIMS successfully separated estradiol glucuronide isomers in positive ion mode and MS/MS via CID enables relative quantitation of each isomer in negative ion mode.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6812596PMC
http://dx.doi.org/10.1007/s13361-019-02272-wDOI Listing

Publication Analysis

Top Keywords

ion mode
16
mass spectrometry
12
estradiol glucuronide
12
ion mobility
8
mobility spectrometry
8
tandem mass
8
glucuronide isomers
8
positive ion
8
negative ion
8
glucuronic acid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!