Cardiovascular implantable electronic devices, which are frequently utilized for many cardiovascular diseases, can become infected, leading to significant morbidity and mortality. This case highlights an unusual presentation of pacemaker generator pocket infection with .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6650214PMC
http://dx.doi.org/10.1080/08998280.2019.1611177DOI Listing

Publication Analysis

Top Keywords

cardiovascular implantable
8
implantable electronic
8
electronic device
4
device infection
4
infection rapidly
4
rapidly growing
4
growing mycobacteria
4
mycobacteria cardiovascular
4
electronic devices
4
devices frequently
4

Similar Publications

Background: Among hypertensive cohorts across different nations, the relationship between the triglyceride-glucose index (TyG) and its conjunction with obesity metrics in relation to cardiovascular disease (CVD) incidence and mortality remains to be elucidated.

Methods: This study enrolled 9,283, 164,357, and 5,334 hypertensives from the National Health and Nutrition Examination Survey (NHANES), UK Biobank (UKBB), and Shanghai Pudong cohort. The related outcomes for CVD were defined by multivariate Cox proportional hazards models, Generalized Additive Models and Mendelian randomization analysis.

View Article and Find Full Text PDF

Enhanced Endothelialization Using Resveratrol-Loaded Polylactic Acid-Coated Left Atrial Appendage Occluders in a Canine Model.

ACS Appl Bio Mater

January 2025

State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Fuwai Hospital, 167 Beilishi Road, Xicheng District, Beijing 100037, China.

Left atrial appendage occlusion (LAAO) is a well-established alternative to anticoagulation therapy for patients with atrial fibrillation who have a high bleeding risk. After occluder implantation, anticoagulation therapy is still required for at least 45 days until complete LAAO is achieved by neoendocardial coverage of the device. We applied a polylactic acid-resveratrol coating to the LAAO membrane to enhance endothelialization with the goal of shortening the anticoagulation therapy duration.

View Article and Find Full Text PDF

Background: Secondary mitral regurgitation (SMR) is a condition affecting the left ventricle (LV) rather than the mitral valve (MV). If the MV remains structurally unchanged, enlargement of the LV or impairment of the papillary muscles can occur. Several mechanical interventions are available to dictate the resolution of MR.

View Article and Find Full Text PDF

Background: Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce.

View Article and Find Full Text PDF

Modification of polylactic acid (PLA) is a promising strategy for the next generation of bioresorbable vascular stent biomaterials. With this focus, FeMOFs nanoparticles was incorporated in PLA, and then post loading of carbon monoxide (CO) was performed by pressurization. It showed FeMOFs incorporation increased hydrophilicity of the surface and CO loading, and CO release was sustained at least for 3 days.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!