Fast fluorometric enumeration of E. coli using passive chip.

J Microbiol Methods

Gazi University, Faculty of Pharmacy, Department of Analytical Chemistry, 06330, Etiler, Ankara, Turkey. Electronic address:

Published: September 2019

In this report, a passive microfluidic chip design was developed for fast and sensitive fluorometric determination of Escherichia coli (E. coli) based on sandwich immunoassay. Initially, magnetic nanoparticles (MNPs) and chitosan modified mercaptopropionic acid capped cadmium telluride (CdTe) quantum dots (QDs) were functionalized with E.coli specific antibody to form a sandwich immunoassay with the E. coli. The magnetic separation and preconcentration of the E.coli from the sample solution was performed in the vial. Conjugation of QDs to the magnetically captured E. coli and washing were performed using a passive type of microchip. The microfluidic chip consists of four microchambers connected to each other by microchannels which act as capillary valves. Signal measurement was performed at the last chamber by using a hand-held spectrofluorometer equipped with a fiber optic reflection probe. The selectivity of the method was tested with Enterobacter aerogenes (E. aerogenes) and Salmonella enteritidis (S. enteritidis), it was observed that these bacteria have no interference effect on E.coli determination. The calibration curve was found to be linear in the range of 10-10 cfu/mL with a correlation coefficient higher than 0.99. The limit of detection was calculated as 5 cfu/mL. The method was successfully applied to spiked tap and lake water samples. The results suggest that the developed method is applicable for on-site E. coli detection and offers several advantages such as large dynamic range, high sensitivity, high selectivity and short analysis time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mimet.2019.105680DOI Listing

Publication Analysis

Top Keywords

microfluidic chip
8
sandwich immunoassay
8
coli
6
fast fluorometric
4
fluorometric enumeration
4
enumeration coli
4
coli passive
4
passive chip
4
chip report
4
report passive
4

Similar Publications

Microfluidics provides cutting-edge technological advancements for the in-channel manipulation and analysis of dissolved macromolecular species. The intrinsic potential of microfluidic devices to control key characteristics of polymer macromolecules such as their size distribution requires unleashing its full capacity. This work proposes a combined approach to analyzing the microscale behavior of polymer solutions and modifying their properties.

View Article and Find Full Text PDF

Measuring virus in biofluids is complicated by confounding biomolecules coisolated with viral nucleic acids. To address this, we developed an affinity-based microfluidic device for specific capture of intact severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Our approach used an engineered angiotensin-converting enzyme 2 to capture intact virus from plasma and other complex biofluids.

View Article and Find Full Text PDF

Tumor-derived extracellular vesicle (tEV)-associated RNAs hold promise as diagnostic biomarkers, but their clinical use is hindered by the rarity of tEVs among nontumor EVs. Here, we present EV-CLIP, a highly sensitive droplet-based digital method for profiling EV RNA. EV-CLIP utilizes the fusion of EVs with charged liposomes (CLIPs) in a microfluidic chip.

View Article and Find Full Text PDF

Selective adsorption of unmethylated DNA on ZnO nanowires for separation of methylated DNA.

Lab Chip

January 2025

Department of Life Science and Technology, Tokyo Institute of Technology, Nagatsuta 4259, Midori-ku, Yokohama 226-8501, Japan.

DNA methylation is a crucial epigenetic modification used as a biomarker for early cancer progression. However, existing methods for DNA methylation analysis are complex, time-consuming, and prone to DNA degradation. This work demonstrates selective capture of unmethylated DNAs using ZnO nanowires without chemical or biological modifications, thereby concentrating methylated DNA, particularly those with high methylation levels that can predict cancer risk.

View Article and Find Full Text PDF

Time-resolved single-cell secretion analysis microfluidics.

Lab Chip

January 2025

Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon Tong, Hong Kong, China.

Revealing how individual cells alter their secretions over time is crucial for understanding their responses to environmental changes. Key questions include: When do cells modify their functions and states? What transitions occur? Insights into the kinetic secretion trajectories of various cell types are essential for unraveling complex biological systems. This review highlights seven microfluidic technologies for time-resolved single-cell secretion analysis: 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!