To investigate 2 generations of balloon-expandable covered stents as potential bridging devices using an in vitro model of stent-graft fenestrations. Twenty BeGraft and 20 BeGraft+ cobalt-chromium stents covered in expanded polytetrafluoroethylene (ePTFE) in 6- and 8-mm diameters were tested in sheets mimicking stent-graft fenestrations. Microscopy and radiography were employed to evaluate stent morphology after flaring. In vitro bench tests measured maximum pullout (perpendicular displacement) and the shear stress (axial displacement) forces needed to dislocate the stents. No alteration of ePTFE coverage was detected in the flared stents. Digital radiography and computed tomography showed marked alteration of the stent geometry, which was more pronounced in the BeGraft group. No fractures were detected. Median (minimum-maximum) pullout forces for the 6-mm stent-grafts were 17.1 N (15.8-19.6) for the BeGraft device and 30.4 N (20.2-31.9) for the BeGraft+ device (p=0.006). Median (minimum-maximum) pullout forces for the 8-mm stent-grafts were 11.3 N (11-12.1) for the BeGraft device and 21.8 N (18.2-25.5) for the BeGraft+ device (p<0.001). The shear stress test showed median forces of 10.5 vs 15.28 N at 150% of the stent diameter for the 6-mm BeGraft and BeGraft+ stent-grafts, respectively, and 15.23 vs 20.72 N at 150% stent diameter for the 8-mm models (p=0.016 and 0.017, respectively). Flaring changed the stent geometry but did not provoke stent fractures. The BeGraft+ is superior to the BeGraft in terms of pullout and shear stress forces, demonstrating greater resilience.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1526602819866435 | DOI Listing |
J Clin Med
December 2024
Department of Vascular Surgery and Transplantation, Medical University of Bialystok, 15-276 Bialystok, Poland.
Stent-graft implantation is a widely recognized method for endovascular treatment of aortic aneurysms. In cases where the aneurysm involves the thoracic and abdominal aorta, repair including fenestrated and branched stent grafts provides a viable alternative. This approach, initially reserved for patients unsuitable for open surgery, has become preferred for anatomically appropriate thoracoabdominal aortic aneurysms.
View Article and Find Full Text PDFEur J Vasc Endovasc Surg
November 2024
Department of Vascular and Endovascular Surgery, General Hospital and Paracelsus Medical University, Nuremberg, Germany.
Objective: The aim of this study was to report outcomes of the BeGraft and BeGraft Plus as bridging covered stents in fenestrated and branched endovascular aneurysm repair (FB-EVAR).
Methods: Patients treated and followed in two institutions receiving at least one BeGraft or BeGraft Plus as bridging covered stent between January 2018 and July 2023 were included.
Results: A total of 765 target vessels (TVs) in 281 patients were aimed to be bridged with the BeGraft or BeGraft Plus.
Rev Esp Enferm Dig
November 2024
Medicina Interna, Hospital Universitario Virgen de la Arrixaca, España.
We present the case of a 73-year-old male, recipient of a liver transplant a year ago, with migration of a "Be-Graft" stent used in a pre-transplant transjugular intrahepatic portosystemic shunt towards the pulmonary artery. The stent was incidentally discovered via imaging tests during hospitalization due to acute cholangitis.
View Article and Find Full Text PDFFront Cardiovasc Med
October 2024
Division of Vascular and Endovascular Surgery, University of Washington, Seattle, WA, United States.
Eur Heart J Case Rep
October 2024
Antwerp Surgical Training, Anatomy and Research Center (ASTARC), University of Antwerp, Universiteitsplein 1, 2610 Antwerpen, Belgium.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!