Safety and Effectiveness of CyPass Supraciliary Micro-Stent in Primary Open-Angle Glaucoma: 5-Year Results from the COMPASS XT Study.

Am J Ophthalmol

Alcon Research LLC, Fort Worth, Texas, USA; Department of Ophthalmology, University of Minnesota, Minneapolis, Minnesota, USA. Electronic address:

Published: December 2019

Purpose: To characterize the long-term (up to 5 years) safety and effectiveness of the supraciliary Micro-Stent (Alcon) implanted at the time of phacoemulsification in eyes with coexisting open-angle glaucoma (OAG) and visually significant cataract.

Design: Three-year safety extension of a 2-year randomized clinical trial.

Methods: Patients from the multicenter Study of an Implantable Device for Lowering Intraocular Pressure in Glaucoma Patients Undergoing Cataract Surgery (COMPASS) trial who underwent Micro-Stent implantation plus phacoemulsification (n = 215) or phacoemulsification alone (n = 67) were evaluated 36, 48, and 60 months postoperatively. The primary outcome measurement was the occurrence of sight-threatening ocular adverse events. Evaluations at each time point included best-corrected visual acuity (BCVA), anterior and posterior segment examinations, tonometry, gonioscopy, pachymetry, perimetry, specular microscopy, and assessment of adverse events.

Results: Three sight-threatening ocular adverse events occurred, 2 in the Micro-Stent group and 1 in the control group, but none of these events was related to the Micro-Stent device. Ocular adverse events were of similar frequencies in both groups, the most common of which were BCVA loss of ≥2 lines compared with best BCVA in COMPASS and worsening of visual field mean defect (VFMD) ≥2.5 dB compared with month 24. Changes in mean BCVA from baseline, clinical examinations, pachymetry, and VFMD were similar in the 2 groups. At 60 months, a higher proportion of subjects in the Micro-Stent group (46%; 95% confidence interval [CI], 38.9%-53.2%) than in the control group (32.1%; 95% CI 19.9%-46.3%) were able to achieve a reduction of ≥20% in intraocular pressure without using hypotensive medication.

Conclusions: Few sight-threatening serious ocular adverse events occurred following Micro-Stent implantation, and clinical evidence of corneal decompensation was minimal.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2019.07.015DOI Listing

Publication Analysis

Top Keywords

ocular adverse
16
adverse events
16
safety effectiveness
8
supraciliary micro-stent
8
open-angle glaucoma
8
intraocular pressure
8
micro-stent implantation
8
phacoemulsification n =
8
sight-threatening ocular
8
events occurred
8

Similar Publications

Ophthalmologic drugs may be delivered to the eye via a number of ways, including topical drops and gels, intraocular injections, and parenteral or oral administration. The inadvertent systemic absorption of these drugs may lead to a myriad of side effects, ranging from benign cosmetic changes to potentially fatal cardiovascular complications. Historically, glaucoma treatment, including β-blockers and α-agonists, have been particularly examined for such events.

View Article and Find Full Text PDF

Ophthalmic corticosteroids-related adverse events: the FDA adverse event reporting system (FAERS) database pharmacovigilance study.

Front Pharmacol

December 2024

Beijing Tongren Eye Center, Beijing Ophthalmology and Visual Science Key Lab, Beijing Tongren Hospital, Capital Medical University, Beijing, China.

Background: Corticosteroids are extensively used in ophthalmology, particularly for treating various inflammatory conditions. Despite their effectiveness, prolonged or high-dose corticosteroid use is associated with significant adverse drug reactions (ADRs), such as increased intraocular pressure, cataract formation, and secondary infections. However, there is currently no systematic study comparing the side effects of ophthalmic corticosteroids.

View Article and Find Full Text PDF

Autologous blood therapy has emerged as a promising modality in managing ocular surface disorders. This review provides a comprehensive overview of the current literature regarding the use of autologous blood in ocular surface disorders, encompassing its physiological basis, clinical applications, techniques, challenges, and future perspectives. The ocular surface, comprising the cornea, conjunctiva, and tear film, plays a critical role in maintaining visual function, and its disruption can lead to various pathological conditions.

View Article and Find Full Text PDF

An 18-year-old woman with a congenital iris stromal cyst was referred for sudden-onset increased intraocular pressure (IOP) that did not respond to medical therapy. Ultrasound biomicroscopy demonstrated synechial angle closure from 9:00 to 12:00 in addition to a large cyst occupying much of the inferior angle. After implantation of an Ahmed glaucoma valve, her visual acuity returned to baseline, and IOP normalized.

View Article and Find Full Text PDF

Recent developments in treatments for both forms of advanced age-related macular degeneration (AMD) have led to the approval of multiple agents and modalities within the last few years. Five new medications for both neovascular AMD (nAMD) and geographic atrophy (GA) secondary to nonexudative AMD (neAMD) have been FDA-approved within the last 5 years, along with a new device designed for sustained drug delivery for nAMD. In nAMD, the newest agents approved by the FDA are brolucizumab (Novartis Pharmaceuticals, Basel, Switzerland), faricimab (F.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!