Metallic objects, such as dental fillings, cause artifacts in computed tomography (CT) scans. We quantify the contouring and dosimetric effects of Orthopedic Metal Artifact Reduction (O-MAR), in head and neck radiotherapy. The ease of organ contouring was assessed by having a radiation oncologist identify the CT data set with or without O-MAR for each of 28 patients that was easier to contour. The effect on contouring was quantified further by having the physician recontour parotid glands, previously drawn by him on the O-MAR scans, on uncorrected scans, and calculating the Dice coefficent (a measure of overlap) for the contours. Radiotherapy plans originally generated on scans reconstructed with O-MAR were recalculated on scans without metal artifact correction. The study was done using the Analytical Anisotropic Algorithm (AAA) dose calculation algorithm. The 15 patients with a planning target volume (PTV) extending to the same slice as the artifacts were used for this part of the study. The normal tissue doses were not significantly affected. The PTV mean dose and V95 were not affected, but the cold spots became less severe in the O-MAR corrected plans, with the minimum point dose on average being 4.1% higher. In 79% of the cases, the radiation oncologist identified the O-MAR scan as easier to contour; in 11% he chose the uncorrected scan and in 11% the scans were judged to have equal quality. A total of nine parotid glands (on both scans-18 contours in total) in 5 patients were recontoured. The average Dice coefficient for parotids drawn with and without O-MAR was found to be 0.775 +/- 0.045. The O-MAR algorithm does not produce a significant dosimetric effect in head and neck plans when using the AAA dose calculation algorithm. It can therefore be used for improved contouring accuracy without updating the critical structure tolerance doses and target coverage expectations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6989373PMC
http://dx.doi.org/10.1016/j.meddos.2019.07.003DOI Listing

Publication Analysis

Top Keywords

metal artifact
12
head neck
12
o-mar
9
effects orthopedic
8
orthopedic metal
8
artifact reduction
8
reduction o-mar
8
o-mar algorithm
8
neck radiotherapy
8
radiation oncologist
8

Similar Publications

Purpose: To quantitatively and qualitatively compare the magnitude of metal total hip arthroplasty-induced imaging artifacts in vivo between 1.5T and 0.55T MRI.

View Article and Find Full Text PDF

This study investigates radiomic efficacy in post-surgical traumatic spinal cord injury (SCI), overcoming MRI limitations from metal artifacts to enhance diagnosis, severity assessment, and lesion characterization or prognosis and therapy guidance. Traumatic spinal cord injury (SCI) causes severe neurological deficits. While MRI allows qualitative injury evaluation, standard imaging alone has limitations for precise SCI diagnosis, severity stratification, and pathology characterization, which are needed to guide prognosis and therapy.

View Article and Find Full Text PDF

Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.

Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.

View Article and Find Full Text PDF

Purpose: Assessment of scaphoid union after operative treatment might be associated with uncertainty, disagreement, and misinterpretation. Union is defined as consolidation on three of four X-ray views. Computed tomography (CT) scans are increasingly used to evaluate union of scaphoid fractures and nonunion.

View Article and Find Full Text PDF

State-of-the-Art Review: Diagnosis and Management of Spinal Implant Infections.

Clin Infect Dis

December 2024

Department of Medical Microbiology and Infection Prevention, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.

Spinal implant infections are a serious complications of instrumented spinal fusion surgeries, carrying high morbidity and complex management challenges. Early postoperative infections may manifest with wound-healing issues, back pain, and fevers. Magnetic resonance imaging (MRI) is the preferred imaging modality, but can be limited by metal artifacts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!