A straightforward and time-efficient technique is presented for recording digital scans in single- and multiple-unit tooth abutments with feather-edge finish lines. The margins of the interim restoration should be precise and sufficiently deep in the sulcus so that the tissues can be properly displaced. Definitive intraoral scans should be made approximately 3 to 4 weeks after the tooth (or teeth) has been prepared to allow healing of the soft tissues. The interim restoration is first removed and then reseated after removing cement residue. First, a scan is made with the interim restoration in place. The abutment tooth or teeth are then erased from the original digital file, the interim restoration is removed again, and a new scan enclosing only the abutment tooth is made.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2019.04.020 | DOI Listing |
J Contemp Dent Pract
September 2024
Department of Prosthodontics and Crown & Bridge, Bharati Vidyapeeth Deemed to be University, Dental College and Hospital, Pune, Maharashtra, India, ORCID: https://orcid.org/0009-0008-7338-1699.
Aim: This study aimed to compare the mixing efficacy and cost-effectiveness of new T-mixer tips against the standard double helical tips for a light-body elastomeric impression and a temporary/interim restorative material using a scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy.
Methodology: Automixed samples ( = 16) were divided into four groups of four samples each: Samples that were mixed with Helical tip for elastomer, T-mixer tip for elastomer, Helical tip for interim restorative material, and T-mixer tip for interim restorative material. These samples were then evaluated for SEM analysis.
Int J Clin Pediatr Dent
November 2024
Department of Pharmacology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.
Aim And Background: Glass ionomer cement (GIC) serves as a widely used restorative dental material, known for its direct bonding to tooth structures and fluoride-releasing properties. This study aims to investigate the enhancement of GIC through the incorporation of a green-mediated nanocomposite comprising chitosan, titanium, zirconium, and hydroxyapatite, with a focus on evaluating the wear resistance of the modified GIC.
Materials And Methods: A one-pot synthesis technique was utilized to prepare a green-mediated nanocomposite incorporating chitosan, titanium, zirconium, and hydroxyapatite nanoparticles.
J Oral Implantol
January 2025
Department of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City, Vietnam.
The reverse scan technique offers several advantages, such as improvements of accuracy and visibility of critical anatomical structures, minimizing chair time, and providing better patient comfort. This was a case report successfully employing the reverse scan technique. A 72-year-old male patient desired to restore his teeth in both jaws, as he experienced difficulty eating and had never worn dentures.
View Article and Find Full Text PDFFront Oral Health
December 2024
Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
Objectives: The influence of printing parameters on the marginal and internal fit of three-dimensional (3D) printed interim fixed partial dentures (IFPDs) has been understudied. This investigation sought to elucidate the impact of printing orientation and post-curing time on these critical factors.
Methods: A total of 260 3-Unit IFDPs were printed using two different resins (130/NextDent C&B MFH and 130/ASIGA DentaTOOTH).
Some of the critical clinical challenges encountered in the treatment of adult patients with deep overbite and worn dentition include correction of deep overbite, establishment of an appropriate occlusal vertical dimension (OVD), and maintenance of long-term occlusal stability. Although Angle's Class II division 2-associated deep anterior overbite is common in orthodontic treatment, simple prosthodontic treatment with great improvement of deep anterior overbite and worn dentition is infrequently reported. A 51-year-old man with Class II Division 2 malocclusion presented with hypo-divergent facial pattern, reduced lower facial height, and protuberant lips.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!