A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Construction and operation of a multiplexed microfiltration device to facilitate rapid pathogen detection. | LitMetric

Millions of Americans contract food poisoning or are affected by microbial pathogens each year. Rapid, sensitive detection of dilute levels of pathogens in foods, produce, water, and biomanufacturing process samples is key to consumer protection; however, current enrichment methods require as much as a full day to enrich viable bacterial pathogens to detectable levels. Our lab previously demonstrated the ability to concentrate and detect dilute levels of pathogens, within 8 hr, from various food matrices using microfiltration in our continuous cell concentration device (i.e., C3D) with one or two filter modules. This short communication describes the design, materials and construction, layout, and operational characteristics of a four filter module multiplexed system based on a four channel device. Benefits are a 2× greater sample capacity than an equivalent duplex system (achieving the same time to result of less than 8 hr from sample preparation to detection), simpler operation, and a footprint enabling operation inside a biosafety cabinet instead of requiring a BSL-2 room. Flow rate variability through four channels fit within an operational envelope of ±3%; flow rates are reproducible from one run to the next thus ensuring relatively simple, concurrent processing of samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/btpr.2889DOI Listing

Publication Analysis

Top Keywords

dilute levels
8
levels pathogens
8
construction operation
4
operation multiplexed
4
multiplexed microfiltration
4
microfiltration device
4
device facilitate
4
facilitate rapid
4
rapid pathogen
4
pathogen detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!