Update on the usefulness of optical coherence tomography in assessing the iridocorneal angle.

Arch Soc Esp Oftalmol (Engl Ed)

Centro Internacional de Oftalmología Avanzada, Madrid, España; Departamento de Oftalmología, Universidad de Extremadura, Badajoz, España.

Published: October 2019

The iridocorneal angle, due to its implications in the physiopathology of aqueous humour drainage, is a fundamental structure of the anterior chamber. Anterior segment optical coherence tomography is a rapid and non-invasive technique that obtains images in vivo. The high resolution allows it to analyse the normal anatomy of the angle, any alterations, and the changes that occur after different therapeutic interventions. Anterior segment optical coherence tomography technology has evolved to provide images that allow the identification and quantification of the angular structures in healthy subjects and in glaucoma patients, and especially the trabecular meshwork and the Schlemm's canal. It also enables the angle width to be quantified, with some objective parameters that have been standardised in recent years, such as the trabecular-iris angle, the angle opening distance, and the trabecular-iris area. This technique has multiple uses in the study of the different mechanisms of angle closure, the evaluation of changes after a laser peripheral iridotomy or iridoplasty after cataract surgery, as well as after the implantation of phakic lenses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.oftal.2019.06.007DOI Listing

Publication Analysis

Top Keywords

optical coherence
12
coherence tomography
12
iridocorneal angle
8
anterior segment
8
segment optical
8
angle
7
update optical
4
tomography assessing
4
assessing iridocorneal
4
angle iridocorneal
4

Similar Publications

Importance: Determining spectacle-corrected visual acuity (VA) is essential when managing many ophthalmic diseases. If artificial intelligence (AI) evaluations of macular images estimated this VA from a fundus image, AI might provide spectacle-corrected VA without technician costs, reduce visit time, or facilitate home monitoring of VA from fundus images obtained outside of the clinic.

Objective: To estimate spectacle-corrected VA measured on a standard eye chart among patients with diabetic macular edema (DME) in clinical practice settings using previously validated AI algorithms evaluating best-corrected VA from fundus photographs in eyes with DME.

View Article and Find Full Text PDF

Diffraction imaging of cells allows rapid phenotyping by the response of intracellular molecules to coherent illumination. However, its ability to distinguish numerous types of human leukocytes remains to be investigated. Here, we show that accurate classification of three lymphocyte subtypes can be achieved with features extracted from cross-polarized diffraction image (p-DI) pairs.

View Article and Find Full Text PDF

Systemic Sodium Iodate Injection as a Model for Expanding Geographic Atrophy.

Transl Vis Sci Technol

January 2025

FM Kirby Center for Molecular Ophthalmology, Scheie Eye Institute, Department of Ophthalmology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA.

Purpose: Geographic atrophy (GA), an advanced form of dry age-related macular degeneration (AMD), has limited treatment options. This study introduces a novel mouse model featuring an expanding GA patch that can be used to test mechanisms and therapeutics.

Methods: C57Bl/6J male mice (n = 96) aged 9-10 weeks received an intraperitoneal (IP) injection of 20 mg/kg sodium iodate (NaIO3).

View Article and Find Full Text PDF

Purpose: To investigate changes in fluid reservoir turbidity parameters over time and its influence on visual performance in eyes with ocular surface disorders (OSD) wearing scleral contact lenses (SL).

Methods: Thirteen eyes with OSD were assessed for corrected distance visual acuity, contrast sensitivity (CS) and fluid reservoir turbidity using anterior segment optical coherence tomography at baseline, after 5 min and 0.5, 1, 2, 3 and 4 h of SL wear on day 1 and after 1 month.

View Article and Find Full Text PDF

Purpose: Anterior segment optical coherence tomography (AS-OCT) is increasingly being used to complement slit-lamp biomicroscopy in the evaluation of corneal infections. Our purpose was to analyze, compare, and correlate the clinical signs elicited by these 2 methods in patients with infectious keratitis (IK).

Methods: Slit-lamp photomicrographs (diffuse and slit beam) and AS-OCT scans were obtained from 20 consecutive patients (21 eyes) with IK.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!