Chiral stationary phases are conveniently used for enantiomeric separation of drugs by liquid chromatography. Consumption of large volumes of hazardous solvents is considered as a common challenge for the sustainability of this technique. To this end, a columnar chromatography has been adopted using 50-mm-length stationary phases. The study comprised five Phenomenex Lux cellulose- and amylose-based columns for the separation of guaifenesin (GUA) enantiomers. In addition, an experimental design was used to optimize the gradient profile for the separation of racemic GUA and ambroxol HCl (AMB) binary mixture. The chromatographic method was achieved using Lux Cellulose-1 (50 × 4.6 mm) as a chiral stationary phase and ethanol/water as a mobile phase with linear gradient elution of 20% to 70% ethanol in 6 minutes at a flow rate of 1.0 mL min and UV detection at 270 nm. Linearity ranges were found to be 50 to 1000 μg mL and 15 to 450 μg mL for each GUA enantiomer and AMB, respectively. Environmental, health and safety tool was used to assess and compare greenness of the proposed and reported methods. Short column indeed reduces the environmental impact by decreasing waste by about 60% and utilizing only 1-mL ethanol in the mobile phase. The proposed method is a safer alternative for the simultaneous determination of drugs in their combined pharmaceutical formulation. The method has been validated and compared favorably with a reported one.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/chir.23116 | DOI Listing |
J Fluoresc
January 2025
College of Chemistry and Chemical Engineering, Donghua University, Shanghai, 201620, China.
Construction of single probes for simultaneous detection of common trivalent metal ions has attracted much attention due to higher efficiency in analysis and cost. A naphthalimide-based fluorescent probe K1 was synthesized for selective detection of Al, Cr and Fe ions. Fluorescence emission intensity at 534 nm of probe K1 in DMSO/HO (9:1, v/v) was significantly enhanced upon addition of Al, Cr and Fe ions while addition of other metal ions (Li, Na, K, Ag, Cu, Fe, Zn, Co, Ni, Mn, Sr, Hg, Ca, Mg, Ce, Bi and Au) did not bring about substantial change in fluorescence emission.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Department of Chemistry, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, 395 007, India.
A fluorescence "turn-off-on" nanoprobe is designed by using europium-doped strontium molybdate perovskite quantum dots (Eu:SMO PQDs) for the sequential detection of hypoxanthine (Hx) and Fe. The Eu:SMO PQDs were prepared by the sol-gel method using Sr(NO), (NH)MoO.4HO, and Eu(OCOCH) as precursors.
View Article and Find Full Text PDFMol Inform
January 2025
Department of Applied Chemistry, School of Science and Technology, Meiji University, 1-1-1 Higashi-Mita, Tama-ku, Kawasaki, Kanagawa 214-8571, Japan.
Recent advances in machine learning have significantly impacted molecular design, notably the molecular generation method combining the chemical variational autoencoder (VAE) with Gaussian mixture regression (GMR). In this method, a mathematical model is constructed with X as the latent variable of the molecule and Y as the target properties and activities. Through direct inverse analysis of this model, it is possible to generate molecules with the desired target properties.
View Article and Find Full Text PDFNucleic Acids Res
January 2025
Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, Jiangnan University, NO.1800, Lihu avenue, Wuxi 214122, China.
Inducible systems are crucial to metabolic engineering and synthetic biology, enabling organisms that function as biosensors and produce valuable compounds. However, almost all inducible systems are strain-specific, limiting comparative analyses and applications across strains rapidly. This study designed and presented a robust workflow for developing the cross-species inducible system.
View Article and Find Full Text PDFNucleic Acids Res
January 2025
Institute of Biotechnology, Life Sciences Center, Vilnius University, Vilnius, 10257, Lithuania.
The expansion of single-cell analytical techniques has empowered the exploration of diverse biological questions at the individual cells. Droplet-based single-cell RNA sequencing (scRNA-seq) methods have been particularly widely used due to their high-throughput capabilities and small reaction volumes. While commercial systems have contributed to the widespread adoption of droplet-based scRNA-seq, their relatively high cost limits the ability to profile large numbers of cells and samples.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!