Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A protein/lanthanide complex (BSA/Tb)-based sensor array in two different pH buffers has been designed for high-throughput recognition and time-resolved fluorescence (TRF) detection of metal ions in biofluids. BSA, which acted as an antenna ligand, can sensitize the fluorescence of Tb (i.e., antenna effect), while the presence of metal ions would lead to the corresponding conformational change of BSA for altering the antenna effect accompanied by a substantial TRF performance of Tb. This principle has also been fully proved by both experimental characterizations and coarse-grained molecular dynamics (CG-MD) studies. By using Tris-HCl buffer with different pHs (at 7.4 and 8.5), 17 metal ions have been well-distinguished by using our proposed BSA/Tb sensor array. Moreover, the sensor array has the potential to discriminate different concentrations of the same metal ions and a mixture of metal ions. Remarkably, the detection of metal ions in biofluids can be realized by utilizing the presented sensor array, verifying its practical applications. The platform avoids the synthesis of multiplex sensing receptors, providing a new method for the construction of convenient and feasible lanthanide complex-based TRF sensing arrays.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.9b01879 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!