Three-voltage linear method to determine ion recombination in proton and light-ion beams.

Phys Med Biol

Molecular Imaging, Radiotherapy and Oncology, Institute for Experimental and Clinical Research, Université catholique de Louvain, Brussels, Belgium. Current email address. Author to whom any correspondence should be addressed.

Published: February 2020

A new practical method to determine the ion recombination correction factor (k ) for plane-parallel and Farmer-type cylindrical chambers in particle beams is investigated. Experimental data were acquired in passively scattered and scanned particle beams and compared with theoretical models developed by Boag and/or Jaffé. The new method, named the three-voltage linear method (3VL-method), is simple and consists of determining the saturation current using the current measured at three voltages in a linear region and dividing it by the current at the operating voltage (V) (even if it is not in the linear region) to obtain k . For plane-parallel chambers, comparing k -values obtained by model fits to values obtained using the 3VL-method, an excellent agreement is found. For cylindrical chambers, recombination is due to volume recombination only. At low voltages, volume recombination is too large and Boag's models are not applicable. However, for Farmer-type chambers (NE2571), using a smaller voltage range, limited down to 100 V, we observe a linear variation of k with 1/V or 1/V for continuous or pulsed beams, respectively. This linearity trend allows applying the 3VL-method to determine k at any polarizing voltage. For the particle beams used, the 3VL-method gives an accurate determination of k at any polarizing voltage. The choice of the three voltages must to be done with care to ensure to be in a linear region. For Roos-type or Markus-type chambers (i.e. chambers with an electrode spacing of 2 mm) and NE2571 chambers, the use of the 3VL-method with 300 V, 200 V and 150 V is adequate. A difference with the 2V-method and some 3V-methods in the literature is that in the 3VL-method the operational voltage does not have to be one of the three voltages. An advantage over a 2V-method is that the 3VL-method can inherently verify if the linearity condition is fulfilled.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab3779DOI Listing

Publication Analysis

Top Keywords

particle beams
12
three voltages
12
linear region
12
three-voltage linear
8
linear method
8
method determine
8
determine ion
8
ion recombination
8
cylindrical chambers
8
volume recombination
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!