Objective: To evaluate the contamination rate of hamstring tendon autografts by comparing two different techniques, and to verify whether intraoperative contamination is associated with the development of clinical infection in patients submitted to reconstruction of the anterior cruciate ligament (ACL).

Methods: A total of 110 hamstring tendon autograft ACL reconstructions were performed and divided into two groups: 1-hamstring tendon retraction technique; and 2 - technique maintaining the tibial insertion of the hamstring tendon. During the preparation, two graft fragments were sent for culturing; the harvesting time, the preparation time, and the total surgery time were measured. Twenty-four hours after the surgery, the C-reactive protein was assayed. The clinical outpatient follow-up was performed up to 180 days postoperatively.

Results: Although there were two postoperative infections, there was no graft contamination or difference between the groups in relation to the graft preparation time and to the 24-hour postoperative C-reactive protein assessment. The classic technique presented a longer graft harvesting time (  = 0.038), and there was no statistical difference between the 2 groups regarding the degree of contamination and consequent clinical infection, although 2 patients in group 2 presented with infection, with negative perioperative cultures.

Conclusion: Based on the results obtained, there was no association between graft contamination and the time or technique of its preparation. In addition, there was also no association between intraoperative contamination and the development of clinical infection, nor was there any sign of an association between the early alteration of C-reactive protein and the onset of infection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6424811PMC
http://dx.doi.org/10.1016/j.rbo.2017.09.008DOI Listing

Publication Analysis

Top Keywords

hamstring tendon
16
clinical infection
12
c-reactive protein
12
tendon autograft
8
anterior cruciate
8
cruciate ligament
8
intraoperative contamination
8
development clinical
8
infection patients
8
harvesting time
8

Similar Publications

Objective: Anterior cruciate ligament (ACL) reconstruction using tendon autograft requires imaging to evaluate graft adequacy. Ultrasound (US) offers an efficient adjunct to MRI; however, the utility of US is variable in prior literature and should be investigated. The primary aim of this study is to provide a statistical appraisal of literature assessing correlation of preoperative US measurements with intraoperative size of autografts during ACL reconstruction.

View Article and Find Full Text PDF

The Structure, Function, and Adaptation of Lower-Limb Aponeuroses: Implications for Myo-Aponeurotic Injury.

Sports Med Open

December 2024

School of Behavioural and Health Sciences, Australian Catholic University, Melbourne, 115 Victoria Parade, Fitzroy, VIC, 3065, Australia.

The aponeurosis is a large fibrous connective tissue structure within and surrounding skeletal muscle and is a critical component of the muscle-tendon unit (MTU). Due to the lack of consensus on terminology and the heterogeneous nature of the aponeurosis between MTUs, there are several questions that remain unanswered. For example, the aponeurosis is often conflated with the free tendon rather than being considered an independent structure.

View Article and Find Full Text PDF

Aims: This study presents clinical outcomes, functional results, and return to sports after anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft or peroneus longus tendon autograft in a randomized controlled trial.

Patients And Methods: Between February 2018 and July 2019, patients who underwent ACL reconstruction were randomly assigned to two groups: hamstring and peroneus longus. Patient related outcome measurements and pain intensity were evaluated using IKDC, Lysholm, and visual analog scores at 3 and 6 months, 1, 2, and 5 years after the surgery.

View Article and Find Full Text PDF

Anterior Cruciate Ligament Reconstruction with Internal Brace Augmentation Results in Fewer Reruptures Compared to Reconstruction without Augmentation.

Rev Bras Ortop (Sao Paulo)

December 2024

Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil.

 To compare the clinical outcomes of anterior cruciate ligament (ACL) reconstruction using autografts with and without internal brace augmentation.  Data from patients who underwent ACL reconstruction with hamstring and quadriceps tendon autografts, with a minimum follow-up of one year, with or without internal brace augmentation were collected prospectively analyzed retrospectively. The Lysholm and Tegner functional scores were collected before and after surgery, as well as data on postoperative complications.

View Article and Find Full Text PDF