Comparison of acquisition protocols for ventilation/perfusion SPECT-a Monte Carlo study.

Phys Med Biol

Medical Radiation Physics and Nuclear Medicine, Imaging and Physiology, Karolinska University Hospital, Stockholm, Sweden. Department of Clinical Science, Intervention and Technology (CLINTEC), Division of Functional Imaging and Technology, Karolinska Institutet, Stockholm, Sweden. Author to whom any corrrespondence should be addressed.

Published: December 2019

One of the most commonly used imaging techniques for diagnosing pulmonary embolism (PE) is ventilation/perfusion (V/P) scintigraphy. The aim of this study was to evaluate the performance of the currently used imaging protocols for V/P single photon emission computed tomography (V/P SPECT) at two nuclear medicine department sites and to investigate the effect of altering important protocol parameters. The Monte Carlo technique was used to simulate 4D digital phantoms with perfusion defects. Six imaging protocols were included in the study and a total of 72 digital patients were simulated. Six dually trained radiologists/nuclear medicine physicians reviewed the images and reported all perfusion mismatch findings. The radiologists also visually graded the image quality. No statistically significant differences in diagnostic performance were found between the studied protocols, but visual grading analysis pointed out one protocol as significantly superior to four of the other protocols. Considering the study results, we have decided to harmonize our clinical protocols for imaging patients with suspected PE. The administered Technegas and macro aggregated albumin activities have been altered, a low energy all purpose collimator is used instead of a low energy high resolution collimator and the acquisition times have been lowered.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab36eeDOI Listing

Publication Analysis

Top Keywords

monte carlo
8
imaging protocols
8
low energy
8
protocols
6
comparison acquisition
4
acquisition protocols
4
protocols ventilation/perfusion
4
ventilation/perfusion spect-a
4
spect-a monte
4
study
4

Similar Publications

Objectives: To assess the pharmacokinetics and pharmacodynamics of imipenem in a retrospective cohort of hospitalized Chinese older patients.

Methods: A population pharmacokinetic (PPK) model was constructed utilizing a nonlinear mixed-effects modeling approach. The final model underwent evaluation through bootstrap resampling and visual predictive checks.

View Article and Find Full Text PDF

Purpose In linac-based stereotactic radiosurgery (SRS) utilizing a multileaf collimator (MLC) for brain metastases (BMs), a volumetric-modulated arc (VMA) technique is indispensable for generating a suitable dose distribution with efficient planning and delivery. However, the optimal calculation grid spacing (GS) and statistical uncertainty (SU) of the Monte Carlo algorithm for VMA optimization have yet to be determined. This planning study aimed to examine the impacts of GS and GU settings on VMA-based SRS planning and to find the optimal combination for templating.

View Article and Find Full Text PDF

Background: Uncertainty about optimal tranexamic acid (TXA) dosage has led to significant practice variation in hip arthroplasty. We aimed to identify the optimal i.v.

View Article and Find Full Text PDF

Importance: Patients with uterine factor infertility (UFI) have few options for family building. Uterus transplant is a feasible treatment for some patients; however, cost remains a significant concern.

Objective: To compare the cost effectiveness of treatment for patients with absolute uterine factor infertility to achieve 1-2 singleton births by gestational carrier or uterus transplant DESIGN: Decision analysis from the United States healthcare sector perspective, with time horizons to achieve one or two singleton births.

View Article and Find Full Text PDF

Heterogeneous head phantom for validating treatment planning system in boron neutron capture therapy.

Appl Radiat Isot

January 2025

Institute of Nuclear Engineering and Science, National Tsing Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan; Nuclear Science and Technology Development Center, National Tsing Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan. Electronic address:

In clinical boron neutron capture therapy (BNCT), the distribution of dose to a heterogeneous medium that is predicted by a treatment planning system (TPS) should be experimentally validated. A head phantom specifically developed for this purpose is described and demonstrated herein. The cylindrical phantom exhibits distinct regions made from four materials (polymethyl methacrylate, calcium phosphate, air, and boric acid) to approximate a head structure with explicitly defined skin, skull, and brain tissue with a cavity and tumor within.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!