Extrinsic ureteral obstruction is caused frequently by pelvic malignancies or metastatic lymphadenopathy, necessitating renal drainage with ureteral stents to prevent renal failure and kidney damage. Understanding the nature of stent behavior under deformation and realistic external pressures may assist in evaluation of stent performance. Few published studies have investigated the flow and mechanical properties of stents within ureters, and none has considered the effects of deformation and compression on flow in realistic, , ureter-stent systems. The purpose of this work was to determine whether or not stent failure is due only to stent compression and deformation in the presence of extrinsic obstruction. We developed an ureter-stent experimental setup, using latex tubing to simulate a flexible ureter connecting a renal unit and a bladder side. We examined flow behavior in three stents (4.8F, 6F, 7F). The ureter-stent configuration was varied, simulating four levels of deformation (0°, 20°, 40°, 60°) and then simulating different external compressive forces on a stented ureter with 40° deformation. A constant, realistic fluid flow was applied through the ureter-stent configurations, and pressure fluctuations in the renal unit were monitored. Deformation alone on four different levels (0°, 20°, 40°, 60°) has essentially no influence on fluid flow and renal pressure variation. Under increasing external compressive forces of 500, 1000, 2000, and up to 5000 g at 40° deformation, no effect on fluid flow and pressure within the renal unit was noted for the 6F and 7F stents. The only exception was for the 4.8F stent, which demonstrated complete failure at compressive forces near 4000 g. Neither realistic extrinsic ureteral compression forces nor ureteral deformation explain the high frequency of stent failure in extrinsic ureteral obstruction. Other factors such as urine composition may be a major contributor to stent failure.

Download full-text PDF

Source
http://dx.doi.org/10.1089/end.2019.0465DOI Listing

Publication Analysis

Top Keywords

stent failure
16
extrinsic ureteral
16
ureteral obstruction
12
renal unit
12
compressive forces
12
fluid flow
12
deformation
9
ureteral deformation
8
stent
8
failure extrinsic
8

Similar Publications

Spontaneous coronary artery dissection (SCAD) is characterized by intramural hematoma in a coronary artery leading to partial or complete vessel obstruction. A 51-year-old female was hospitalized with acute myocardial infarction and cardiogenic shock. She was diagnosed with severe SCAD, affecting the proximal left coronary artery.

View Article and Find Full Text PDF

Mid-term outcomes of frozen elephant trunk for chronic aortic dissection.

Can J Cardiol

January 2025

Cardiovascular department, Cardiology Research Institute, Tomsk National Research Medical Centre, Russian Academy of Sciences, Tomsk, Russian Federation.

Background: The aim of the study was to analyze the mid-term outcomes of the frozen elephant trunk (FET) procedure for chronic aortic dissection (СAD).

Methods: From March 2012 to December 2022, 123 FET procedures were performed in patients with acute and chronic aortic dissection as well as aortic aneurysm. Fifty-five patients with chronic aortic dissection (CAD) were eligible for study.

View Article and Find Full Text PDF

Intracardiac migration of inferior vena cava (IVC) filter or stent is a rare but potentially fatal complication of endovascular venous device placement. There is no consensus whether migrated stents should be surgically removed by open cardiac surgery or retrieved by the percutaneous endovascular route and whether an intervention should be performed immediately or expectantly. Herein, we report a 39-year-old female who received emergent left lobe living donor liver transplantation (LDLT) owing to posthepatectomy liver failure.

View Article and Find Full Text PDF

Objective: The study objective was to assess the efficacity of different surgical strategies for atrioesophageal fistula after catheter ablation of atrial fibrillation.

Methods: Between January 2010 and April 2023, all patients with a diagnosis of atrioesophageal fistula or pericardo-esophageal fistula after catheter ablation of atrial fibrillation were analyzed retrospectively from the French database EPITHOR. Patients without surgical management were excluded.

View Article and Find Full Text PDF

Background: This study aims to evaluate the clinical efficacy of pancreatic duct stenting in the treatment of SAP, providing reference for clinical diagnosis and treatment.

Methods: A retrospective analysis was conducted on clinical data from patients with SAP admitted to the General Hospital of Ningxia Medical University from June 1, 2019 to December 31, 2022. A total of 51 patients were included (33 males, 18 females).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!