Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: This study aims to investigate the influence of temperatures of 20 °C and 37 °C on the resistance to cyclic fatigue of NiTi instruments with different heat treatments, as tested in severely curved simulated canals.
Materials And Methods: Seventy-two instruments were distributed according to the temperature used (20 °C and 37 °C): XP-endo Shaper (30/0.01), ProDesign Logic (30/0.05), and iRaCe (30/0.04). The instruments were rotated freely until the occurrence of fracture inside an artificial severely curved stainless steel canal, which had a 90° angle of curvature and a curvature radius of 5 mm. Kolmogorov-Smirnov, Wilcoxon, ANOVA, and Kruskal-Wallis tests were performed. A value of <0.05 was considered statistically significant.
Results: XP-endo Shaper instruments presented higher NCF values and time to failure compared with ProDesign Logic and iRaCe instruments at 20 °C and 37 °C ( < 0.001).
Conclusion: Within the limitations of this study, the results show that the body temperature (37 °C) significantly lowers the resistance to cyclic fatigue of all instruments compared with 20 °C.
Clinical Significance: Body temperature is an important factor in the results of cyclic fatigue tests.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!