Weight-bearing long-leg radiographs are commonly used in orthopaedic surgery. Measured parameters, however, change when radiographs are conducted in different rotational positions of the leg. It was hypothesized that rotational errors are regularly present in long-leg radiographs resulting in wrong measurements. In 100 consecutive long-leg radiographs conducted according to the method of Paley, rotation was assessed by fibular overlap. Angular parameters in radiographs (mechanical lateral proximal femoral angle (mLPFA), mechanical lateral distal femoral angle (mLDFA), angle between the anatomical and mechanical femoral axis (AMA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal tibial angle (mLDTA), and the mechanical femoral and tibial axis (mFA-mTA) were measured and deviations related to malrotation calculated. An average internal rotation of 8 degrees was found in lower limbs showing a range between 29 degrees of internal and 22 degrees of external rotation. As a result, mean differences before and after rotational correction for measured parameters (mLPFA, mLDFA, AMA, mMPTA, mLDTA, mFA-mTA) ranged between 0.4 and 1.7 degrees (-2.1; 5.6 95% confidence interval [CI]). In conclusion, malrotation of lower limbs is regularly present in long-leg radiographs. As all measured parameters are influenced by malrotation, correct lower limb rotation needs to be verified.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0039-1693668 | DOI Listing |
Acta Chir Orthop Traumatol Cech
January 2025
Klinika dětské chirurgie, ortopedie a traumatologie Fakultní nemocnice Brno.
Purpose Of The Study: Temporary hemiepiphyseodesis using figure-eight plates is currently one of the main surgical techniques to correct axial deformities of lower limbs in paediatric patients. Comprehensive analysis, correct indication and monitoring of treatment are the basic prerequisites for successful therapy. The aim of the study was to analyse parameters that could become an alternative to standard parameters used nowadays, namely the inserted screw angle (SA), and a new parameter - condylar ratio (CR).
View Article and Find Full Text PDFLife (Basel)
November 2024
Pediatric Orthopedics and Traumatology, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
Background: Fibrous dysplasia (FD) is a rare condition in which normal spongy and cortical bone is replaced by non-neoplastic fibrous tissue, leading to weakened bone matrix and increased risk of pathological fractures and deformities. Treating these deformities poses a significant challenge for surgeons. While various cases of surgical stabilization and limb lengthening using intramedullary nails have been reported, there is limited evidence on the use of Motorized Intramedullary Limb-Lengthening Nails (MILLNs) in FD patients.
View Article and Find Full Text PDFArthroplast Today
December 2024
Department of Orthopedic Surgery, University of California Davis Medical Center, Sacramento, CA.
Background: The study focused on kinematically aligned total knee arthroplasty (KA TKA). It identified which coronal plane alignment of the knee (CPAK) types are associated with a higher proportion of medial deviation of the 6° prosthetic trochlear groove (PTG) relative to the quadriceps' line of pull and whether medial deviation adversely affected the Forgotten Joint Score (FJS). The research calculated the minimum PTG angle required to prevent medial deviation by at least 2° in all patients.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopedics, Balgrist University Hospital University of Zurich Zurich Switzerland.
Purpose: The goals of this study were (1) to assess whether the preoperative difference between modalities and extent of deformity are associated with a higher difference between planned and achieved surgical correction and (2) if they yield a higher probability of intraoperative adjustments.
Methods: Retrospective single-centre analysis of patients undergoing patient-specific instrumented (PSI) total knee arthroplasty (TKA). Preoperative radiographic parameters were analysed on weightbearing (WB) long-leg radiographs (LLR) and nonweightbearing (NWB) computed tomography (CT).
Arch Orthop Trauma Surg
December 2024
Sitaram Bhartia Institute of Science and Research, New Delhi, India.
Purpose: Achieving precise postoperative alignment is critical for the long-term success of total knee arthroplasty (TKA). Long-leg standing radiograph (LLR) at 6 weeks post-op is the gold standard for assessing alignment, but its reliance on weight-bearing and positioning makes it less practical in the early postoperative period. Supine computed tomography scanogram (CTS) offers a potential alternative.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!