Use of a hand-held spectroradiometer for the measurement of neonatal phototherapy lamp outputs.

Med Eng Phys

Department of Neonatology, University Hospital, Coventry, CV2 2DX, United Kingdom.

Published: November 2019

The measurement capability of a hand-held spectroradiometer for validation of phototherapy light treatment for neonates is described. This function is compared with that of a double grating monochromator system with photomultiplier detector, where parameters evaluated included wavelength accuracy and accuracy of irradiance within set wavelength intervals - 460 nm to 490 nm and 400 nm to 550 nm. Measurements carried out in a clinical setting revealed that the hand-held spectroradiometer provided an acceptable level of accuracy for determining output characteristics of the phototherapy devices investigated. It was observed that measurement errors were more significant for studies involving direct contact with light emitting surfaces. It was identified that the spectral resolution of the MSC15 device could act to degrade the accuracy of the device where narrow spectrum peaks occurred around the limits of specific identified bandwidths - such as at 460 nm and 490 nm. This was identified not to be an issue with typical light emitting diode phototherapy systems, where the spectral outputs do not contain narrow spectral components. The device lends itself also to use by clinical staff in the clinical environment to verify the output of phototherapy lamps. The availability of such hand-held spectroradiometer devices represents an advance on the use of output meters suppled by equipment manufacturers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2019.07.001DOI Listing

Publication Analysis

Top Keywords

hand-held spectroradiometer
16
460 nm 490 nm
8
light emitting
8
phototherapy
5
hand-held
4
spectroradiometer measurement
4
measurement neonatal
4
neonatal phototherapy
4
phototherapy lamp
4
lamp outputs
4

Similar Publications

Evaluating potential of leaf reflectance spectra to monitor plant genetic variation.

Plant Methods

October 2023

Department of Geography, Faculty of Science, University of Zurich, Winterthurerstrasse 190, 8057, Zurich, Switzerland.

Remote sensing of vegetation by spectroscopy is increasingly used to characterize trait distributions in plant communities. How leaves interact with electromagnetic radiation is determined by their structure and contents of pigments, water, and abundant dry matter constituents like lignins, phenolics, and proteins. High-resolution ("hyperspectral") spectroscopy can characterize trait variation at finer scales, and may help to reveal underlying genetic variation-information important for assessing the potential of populations to adapt to global change.

View Article and Find Full Text PDF

Rice is the staple food of more than half of the population of the world and India as well. One of the major constraints in rice production is frequent occurrence of pests and diseases and one of them is rice blast which often causes yield loss varying from 10 to 30%. Conventional approaches for disease assessment are time-consuming, expensive, and not real-time; alternately, sensor-based approach is rapid, non-invasive and can be scaled up in large areas with minimum time and effort.

View Article and Find Full Text PDF

Background: Given the increasing use of photo-activated resins in dentistry, dentists and researchers need a user-friendly dental radiometer to measure the power output from dental light-curing units (LCUs).

Objective: Our goal was to measure the accuracy of two brands of dental radiometers in reporting the power (mW) from twelve brands of contemporary LCUs compared to a 'gold standard' (GS) reference value obtained from an integrating sphere attached to a fiberoptic spectroradiometer.

Methods: The power output was measured from two units of 12 brands of LCUs, five times on the ''GS" system, five times on two Bluephase Meter II dental radiometers, and five times on two Mini Gig hand-held spectroradiometers.

View Article and Find Full Text PDF

Preliminary observations of a system for determination of phototherapy exposure over a neonate body shape.

Med Eng Phys

September 2021

Department of Clinical Physics and Bioengineering FM Building, University Hospital Coventry, CV2 2DX, United Kingdom.

While it is possible to determine the irradiance and spectral content for a given neonatal phototherapy device at various locations over a neonate's surface, this does not allow estimation of the total rate of energy delivery within a specific spectral range over the neonate's exposed body surface. A series of 192 blue wavelength enhanced silicon photodiodes was distributed over the surface of a commercially available newborn body shape and connected to a specially designed interface circuit. Placement of photosensors over the surface of the baby shape was determined with consideration of the surface area of twelve specific anatomical areas where each was allocated 16 individual photodiodes.

View Article and Find Full Text PDF

The measurement capability of a hand-held spectroradiometer for validation of phototherapy light treatment for neonates is described. This function is compared with that of a double grating monochromator system with photomultiplier detector, where parameters evaluated included wavelength accuracy and accuracy of irradiance within set wavelength intervals - 460 nm to 490 nm and 400 nm to 550 nm. Measurements carried out in a clinical setting revealed that the hand-held spectroradiometer provided an acceptable level of accuracy for determining output characteristics of the phototherapy devices investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!