A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Method development for analyzing ultratrace polyhalogenated carbazoles in soil and sediment. | LitMetric

In the past few years, polyhalogenated carbazoles (PHCZs) have been of increasing concern because their structure is similar to that of legacy POPs. In the present study, an analytical method, including intensive cleanup and fractionation procedures in combination with instrumental parameters, was developed to determine ultratrace polyhalogenated carbazoles (PHCZs) in soil and sediment. The eluting sorbents, volume and packing of the column were optimized. Our results showed that 5 g of florisil and 4 g of silica gel under 150 mL of hexane/DCM = 3:1 presented good performance in terms of recovery and repeatability. GC-HRMS, GC-MS/MS (EI-MRM) and GC-MS (EI-SIM) were applied to compare the performance of PHCZ analysis. For sensitivity, EI-MRM presents method detection limits comparable to those of GC-HRMS and much lower than those of EI-SIM. Regarding selectivity, GC-HRMS performed better than the other two techniques since GC-HRMS can reduce interference from perfluorokerosene (PFK) and DDX (DDT, DDE, and DDD) due to its high resolution. GC-HRMS was then further optimized by shortening the run time and modifying the SIM ion. The final method was successfully applied to determine PHCZs in soil and sediment, and the target compounds had almost 100% detection frequency in the samples. The ubiquitous presence of PHCZ in soil and sediment calls for a further investigation of its source, distribution and degradation in the environment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ecoenv.2019.109470DOI Listing

Publication Analysis

Top Keywords

soil sediment
16
polyhalogenated carbazoles
12
ultratrace polyhalogenated
8
carbazoles phczs
8
phczs soil
8
gc-hrms
5
method
4
method development
4
development analyzing
4
analyzing ultratrace
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!