Background: Oral inhalation is the main drug delivery route for treating obstructive lung conditions. Thus, many inhaler devices with various design and pharmaceutical formulation have been introduced. The fine particle dose (FPD) and mass median aerodynamic diameter (MMAD ≤ 5 μm) of the aerosol delivered dose (DD) dictate the therapeutically effective peripheral lung deposition. This study evaluated the in vitro aerosol emission performance of tiotropium bromide emitted from Spiriva® Respimat® soft mist inhalers (R) after living under patients' real-world, post-dispensing handling environments.
Methods: This was a two-stage investigation. In the first clinical stage, research ethical approval was obtained to enrol patients already been using R for at least 3 months. Those who signed consent were given both new R to use and temperature and relative humidity (RH) handheld, portable data loggers to keep in the vicinity of the given R. The participants returned the given R and data loggers after 2 weeks. Patient recruitment took place in Amman, Jordan, during the summer (RS) and winter (RW). Subsequently, in the second laboratory stage, other R were strictly stored at an average of 21.0 °C and 46.9% RH as control (RC). The Next Generation Impactor (NGI) was used to evaluate the RS, RW and RC. The NGI was operated at a flow rate of 30 L/min.
Results: The RS were exposed to an average (range) 23.6 °C (18.2-37.5 °C) and 43.8% RH (21.4-60.0% RH) that were statistically comparable (p > 0.05) to that of the RW; 17.3 °C (13.2-26.7 °C) and 52.8% RH (26.3-69.1% RH). The RW and RC retention environments were statistically different (p < 0.05), whilst the RS and RC had comparable (p > 0.05) conditions. No significant differences (p > 0.05) were found in the tiotropium bromide DD (2.39 vs 2.43 μg), FPD (0.88 vs 0.90 μg) and MMAD (5.1 vs 4.98 μm) between the RS and RW, respectively. Compared to the RC inhalers, both the RS and RW devices had significantly higher FPD and relatively smaller tiotropium bromide particles.
Conclusions: Using the R under the fluctuating summer and winter environments of our patients would not affect its overall tiotropium bromide emission performance. The significant increase in the respirable mass of the RS and RW might be offset by the increase in particles <1 μm particularly in patients with poor inhaler technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.pupt.2019.101829 | DOI Listing |
Drug Deliv Transl Res
December 2024
Shobhaben Pratapbhai Patel School of Pharmacy and Technology Management, SVKM'S NMIMS, V. L. Mehta Road, Vile Parle (W), Mumbai, India.
The present study aimed to synthesize tiotropium bromide (TIO)-loaded generation 5 polyamidoamine dendrimers (TIO-PAMAM-G5-DMs) using a solvent-free microwave assisted synthesis (MAS) for the treatment of pulmonary acidosis, a condition associated with decreased blood pH due to bronchoconstriction. The encapsulation of TIO into PAMAM-G5-DMs was achieved using MAS Michael addition and amidation reactions, following green chemistry principles. The DMs demonstrated particle size of 460.
View Article and Find Full Text PDFHeliyon
October 2024
Department of Oral and Maxillofacial Surgery, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huaian, 223300, Jiangsu Province, China.
BMC Pulm Med
September 2024
Centre de Recherche de l'Institut universitaire de cardiologie et de pneumologie de Québec, Université Laval, 2725, chemin Sainte-Foy, Québec, QC, G1V 4G5, Canada.
Background: Little is known about the trends in morbidity and mortality at the population level that followed the introduction of newer once-daily long-acting bronchodilators for COPD. The purpose of the study was to evaluate whether the availability of new bronchodilators was associated with changes in the temporal trends in severe COPD exacerbations and mortality between 2007 and 2018 in the older population with COPD; and whether this association was homogeneous across sex and socioeconomic status classes.
Methods: We used an interrupted time-series and three segments multivariate autoregressive models to evaluate the adjusted changes in slopes (i.
Urology
December 2024
Department of Urology, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China. Electronic address:
Objective: To explore the association between drugs and urinary retention using the FDA Adverse Event Reporting System (FAERs) database and Mendelian randomization (MR) analysis, providing preliminary insights into the underlying mechanisms.
Methods: Drug-adverse reaction reports from the FAERs database from 2004 to 2023 were obtained, and MR analysis was conducted to further validate the causal relationship between drugs and urinary retention using genetic data provided by the IEU OpenGWAS project.
Results: We identified 78 drugs associated with urinary retention, including Mirabegron, Tiotropium, Quetiapine, Amlodipine, etc.
BMC Pulm Med
August 2024
Department of Ophthalmology, Giresun University Faculty of Medicine, Giresun, Turkey.