Since its starting point in 1929, human scalp electroencephalography (EEG) has been routinely interpreted by visual inspection of waveforms using the assumption that the activity at a given electrode is a representation of the activity of the cerebral cortex under it, but such a method has some limitations. In this review, we will discuss three advanced methods to obtain valuable information from scalp EEG in epilepsy using innovative technologies. Authors who had previous publications in the field provided a narrative review. Spike voltage topography of interictal spikes is a potential way to improve non-invasive EEG localization in focal epilepsies. Electrical source imaging is also a complementary technique in localization of the epileptogenic zone in patients who are candidates for epilepsy surgery. Quantitative EEG simplifies the large amount of information in continuous EEG by providing a static graphical display. Scalp electroencephalography has the potential to offer more spatial and temporal information than the traditional way of visual inspection alone in patients with epilepsy. Fortunately, with the help of modern digital EEG equipment and computer-assisted analysis, this information is more accessible.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10072-019-04026-8DOI Listing

Publication Analysis

Top Keywords

visual inspection
12
scalp electroencephalography
8
eeg
6
electroencephalography epilepsy
4
epilepsy visual
4
inspection starting
4
starting point
4
point 1929
4
1929 human
4
human scalp
4

Similar Publications

: Since 2008, following clinical studies conducted on children that revealed the ability of the β-adrenergic antagonist propranolol to inhibit capillary growth in infantile hemangiomas (IHs), its oral administration has become the first-line treatment for IHs. Although oral propranolol therapy at a dosage of 3 mg/kg/die is effective, it can cause systemic adverse reactions. This therapy is not necessarily applicable to all patients.

View Article and Find Full Text PDF

Parenteral drug products manufactured under GMP conditions should be visually inspected for defects and particulate contamination by trained and qualified personnel. Although personnel qualification is required, no practical protocols or formal guidelines are available for the development of qualification test sets (QTSs) used for qualification procedures. The current practice is to either procure a standardized QTS from a commercial supplier or amass sufficient manufacturing rejects during visual inspection procedures to compile in-house QTSs.

View Article and Find Full Text PDF

Improving Industrial Quality Control: A Transfer Learning Approach to Surface Defect Detection.

Sensors (Basel)

January 2025

Centre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.

To automate the quality control of painted surfaces of heating devices, an automatic defect detection and classification system was developed by combining deflectometry and bright light-based illumination on the image acquisition, deep learning models for the classification of non-defective (OK) and defective (NOK) surfaces that fused dual-modal information at the decision level, and an online network for information dispatching and visualization. Three decision-making algorithms were tested for implementation: a new model built and trained from scratch and transfer learning of pre-trained networks (ResNet-50 and Inception V3). The results revealed that the two illumination modes employed widened the type of defects that could be identified with this system, while maintaining its lower computational complexity by performing multi-modal fusion at the decision level.

View Article and Find Full Text PDF

Benzo[1,2-b:6,5-b']dithiophene-4,5-diamine: A New Fluorescent Probe for the High-Sensitivity and Real-Time Visual Monitoring of Phosgene.

Sensors (Basel)

January 2025

State Key Laboratory of Marine Resource Utilization in South China Sea, School of Chemistry and Chemical Engineering, Hainan University, Haikou 570228, China.

The detection of highly toxic chemicals such as phosgene is crucial for addressing the severe threats to human health and public safety posed by terrorist attacks and industrial mishaps. However, timely and precise monitoring of phosgene at a low cost remains a significant challenge. This work is the first to report a novel fluorescent system based on the Intramolecular Charge Transfer (ICT) effect, which can rapidly detect phosgene in both solution and gas phases with high sensitivity by integrating a benzo[1,2-b:6,5-b']dithiophene-4,5-diamine (BDTA) probe.

View Article and Find Full Text PDF

Based on the Geometric Characteristics of Binocular Imaging for Yarn Remaining Detection.

Sensors (Basel)

January 2025

School of Mechanical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China.

The automated detection of yarn margins is crucial for ensuring the continuity and quality of production in textile workshops. Traditional methods rely on workers visually inspecting the yarn margin to determine the timing of replacement; these methods fail to provide real-time data and cannot meet the precise scheduling requirements of modern production. The complex environmental conditions in textile workshops, combined with the cylindrical shape and repetitive textural features of yarn bobbins, limit the application of traditional visual solutions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!