Sex differences in behavioral and neural characteristics can be caused by cultural influences but also by sex-based differences in neurophysiological and sensorimotor features. Since signal-response systems influence decision-making, cooperative and collaborative behaviors, the anatomical or physiological bases for any sex-based difference in sensory mechanisms are important to explore. Here, we use uniform scaling and nonparametric representations of the human cochlea, the main organ of hearing that imprints its adult-like morphology within the petrosal bone from birth. We observe a sex-differentiated torsion along the 3D cochlear curve in samples of 94 adults and 22 juvenile skeletons from cross-cultural contexts. The cochlear sexual dimorphism measured in our study allows sex assessment from the human skeleton with a mean accuracy ranging from 0.91 to 0.93 throughout life. We conclude that the human cochlea is sex-typed from an early post-natal age. This, for the first time, allows nondestructive sex determination of juveniles' skeletal remains in which the biomolecules are too degraded for study but in which the petrosal is preserved, one of the most common bone within archaeological assemblages. Our observed sex-typed cochlear shape from birth is likely associated with complex evolutionary processes in modern humans for reasons not yet fully understood.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6659711PMC
http://dx.doi.org/10.1038/s41598-019-47433-9DOI Listing

Publication Analysis

Top Keywords

cochlear shape
8
organ hearing
8
human cochlea
8
cochlear
4
shape reveals
4
human
4
reveals human
4
human organ
4
hearing sex-typed
4
sex-typed birth
4

Similar Publications

Cochlear Organ Dissection, Immunostaining, and Confocal Imaging in Mice.

Bio Protoc

January 2025

ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, China.

The organ of Corti, located in the inner ear, is the primary organ responsible for animal hearing. Each hair cell has a V-shaped or U-shaped hair bundle composed of actin-filled stereocilia and a kinocilium supported by true transport microtubules. Damage to these structures due to noise exposure, drug toxicity, aging, or environmental factors can lead to hearing loss and other disorders.

View Article and Find Full Text PDF

Introduction: Despite improved hearing, children who receive cochlear implants (CIs) at a later age encounter difficulties in adapting to society, exposing them to psychological and social risks. This study contributes to the conceptualisation of preventive interventions in schools to address potential issues so that these children can play a more active role in society.

Methods: A total of 52 children (aged 3-12 years) who received CIs at 30 months of age were assessed using the Asahide-Shiki Social Adaptive skills test, which evaluates children's social skills on four domains: (A) language, (B) everyday life, (C) social life, (D) communication.

View Article and Find Full Text PDF

The refinement of neural circuits towards mature function is driven during development by patterned spontaneous calcium-dependent electrical activity. In the auditory system, this sensory-independent activity arises in the pre-hearing cochlea and regulates the survival and refinement of the auditory pathway. However, the origin and interplay of calcium signals during cochlear development is unknown in vivo.

View Article and Find Full Text PDF

Thermally Drawn Shape and Stiffness Programmable Fibers for Medical Devices.

Adv Healthc Mater

December 2024

Department of Metabolism, Digestion, and Reproduction, Faculty of Medicine, Imperial College London, London, SW7 2AZ, UK.

Article Synopsis
  • Shape Memory Polymers (SMPs) have great potential for medical applications, but their usage has been limited due to challenges in processing and production.
  • This study introduces a thermal drawing technique to create Shape Memory Polymer Fibers (SMPFs) that allow for programmable stiffness and shape control, specifically designed for medical devices.
  • The research explores various applications of these SMPFs in medical devices like adjustable catheters, neural interfaces, and cochlear implants, demonstrating their versatility and potential in programmable mechanical functions.
View Article and Find Full Text PDF

Fluid-Structure Interaction Analysis of Trapezoidal and Arc-Shaped Membranes Mimicking the Organ of Corti.

Int J Numer Method Biomed Eng

January 2025

Department of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan.

In a previous study [H. Shintaku et al., Sensors and Actuators A: Physical 158 (2010): 183-192], an artificially developed auditory sensor device showed a frequency selectivity in the range from 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!