: To investigate the relationship between capsular bend type and posterior capsule opacification (PCO) at a three-dimensional (3D) level using high-speed swept-source optical coherence tomography (SS-OCT).: This was a retrospective study. A total of 99 eyes that underwent standard cataract surgery with phacoemulsification 2 years ago were analyzed. Standard SS-OCT radial scanning was performed in all eyes and the obtained photos were used for morphological observations of the capsular bend-IOL complex, the adhesion of posterior capsule to the IOL optic, and the position of the anterior capsulorhexis. Digital retroillumination photographs were taken of the posterior capsule of each eye to evaluate PCO (scoring and area).: In terms of the PCO score and area, there was no statistical difference between eyes with complete and incomplete adhesion of posterior capsule to IOL (both > .05), whereas the partial overlap group showed a statistical difference greater than the total overlap group ( < .05). There were two types of capsular bends, completed adhesion (CA) and incomplete adhesion (IA). IA was divided into funnel adhesion (IA-F), parallel adhesion (IA-P), and detached adhesion (IA-D). The incomplete adhesion index (IAI) varied between eyes and ranged from 0 to 1. The PCO score and area in the high IAI group (higher than 0.50) were significantly greater than the low IAI group (< 0.50) ( < .05). In addition, the PCO score and area were significantly higher in the cohort with at least one IA-D capsular bend in six districts to the group that did not have IA-D capsular bend ( < .05).: Complete or incomplete adhesion of the posterior capsule to the IOL optic may not be necessary for the development of PCO. Our study suggests that capsular bend type may be used as an index to predict PCO.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02713683.2019.1645183 | DOI Listing |
Purpose: To observe and explore the correlation between visual outcomes and intraocular lens (IOL) stability after tri-focal IOL implantation in eyes with high myopia.
Methods: Patients with highly myopic cataract (axial length > 26 mm) were enrolled in this prospective study. Thirty-one eyes (31 patients) received implantation of a trifocal IOL (AcrySof IQ PanOptix TFNT00).
J Cataract Refract Surg
November 2024
Shengli Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, China.
Purpose: To evaluate intraocular lens (IOL) rotational stability and capsular fusion process after cataract surgery with and without primary posterior continuous curvilinear capsulorrhexis (PPCCC).
Setting: Fujian Provincial Hospital, Fujian, China.
Design: Prospective, intraindividual, randomized clinical trial.
Oper Neurosurg (Hagerstown)
October 2024
Rhoton Neurosurgery and Otolaryngology Surgical Anatomy Program, Mayo Clinic, Rochester, Minnesota, USA.
Background And Objective: Endoscopic endonasal approaches to treat cavernous sinus lesions require detailed knowledge of the origin, course, and anatomic variations of the branches of the cavernous internal carotid artery (cICA) because inadvertent avulsion can cause intraoperative ICA injury. We aim to study the origin and course of the branches of the cICA from an endoscopic endonasal perspective and relate these branches to surgically relevant anatomic references.
Methods: Sixty sides of 30 formalin-fixed specimens were dissected to identify the origin and course of cICA branches, including the inferolateral trunk (ILT), the meningohypophyseal trunk (MHT), anterior and inferior McConnell's capsular arteries (MCAs), and the superolateral trunk (SLT).
Ophthalmol Ther
June 2024
Eye Hospital, Wenzhou Medical University, 618 East Feng-Qi Road, Hangzhou, 310000, Zhejiang, China.
Introduction: The aim of this work is to investigate the dynamic changes of capsular-intraocular lens (IOL) adhesion in plate-haptic hydrophilic and loop-haptic hydrophobic eyes.
Methods: Cataract eyes that met the inclusion criteria were randomly assigned to receive implantation of a plate-haptic hydrophilic or loop-haptic IOL. The anterior capsular adhesion, posterior capsular adhesion, and the configurations of the capsular bend were evaluated using swept-source optical coherence tomography at 1 day, 1 week, 1 month, and 3 months postoperatively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!