A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A performance comparison of the 20 and 30 meter six-minute walk tests among middle aged and older adults. | LitMetric

A performance comparison of the 20 and 30 meter six-minute walk tests among middle aged and older adults.

Physiother Theory Pract

Núcleo de Assistência, Ensino e Pesquisa em Reabilitação Pulmonar - NuReab, Universidade do Estado de Santa Catarina, Florianópolis, SC, Brazil.

Published: July 2021

: To compare the performance of the Six-Minute Walk Test on 20-meter (6MWT) and 30-meter (6MWT) tracks and to test the validity and reliability of the 6MWT in middle-aged and older adults.: The subjects underwent lung function assessment and performed the 6MWT and 6MWT. Student´s tests or Wilcoxon tests were used to compare the variables. The Pearson or Spearman correlation coefficients were used to evaluate the validity of the 6MWT and the reliability of the 6MWT. The 6MWT was tested by the two-way mixed model of the Intraclass Correlation Coefficient (ICC 3,1).: Twenty-five subjects (age: 60 ± 10 years) walked, on average, 11.0 ± 21.9 m more in the 6MWT than in the 6MWT ( < .05). The walking distance, the number of steps, the energy expenditure and the movement intensity between the 6MWT and 6MWT was correlated (r = 0.95; r = 0.81; r = 0.91; r = 0.67; respectively, < .001). The walking distances showed high reliability and were similar between test and re-test in the 6MWT (544 ± 72.1 vs. 551 ± 70.5; < .05; ICC = 0.97) and in the 6MWT (533 ± 73.1 vs. 532 ± 59.1; < .05; ICC = 0.87).: The 6MWT performance is lower than the 6MWT However, this difference is not clinically relevant. Additionally, the 6MWT is a valid and reproducible test to assess the functional capacity of middle-aged and older adults.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09593985.2019.1645251DOI Listing

Publication Analysis

Top Keywords

6mwt
17
6mwt 6mwt
16
older adults
12
six-minute walk
8
reliability 6mwt
8
middle-aged older
8
performance comparison
4
comparison meter
4
meter six-minute
4
walk tests
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!