Microcomputed tomographic investigation of the trepan bur/microtube technique for the removal of fractured instruments from root canals without a dental operating microscope.

Clin Oral Investig

State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Cariology and Endodontics West China Hospital of Stomatology, Sichuan University, #14, 3rd Section of RenMin South Road, Chengdu, 610041, China.

Published: May 2020

Objectives: The aim of this study was to evaluate the removal of fractured instruments in mandibular incisor canals by using the trepan bur/microtube technique without a dental operating microscope (DOM).

Materials And Methods: Thirty-four mandibular incisors were selected, and 5-mm apical segments of #25/.06 taper K3 NiTi instruments were fractured in the apical portion of each canal. Coronal enlargement was performed, and a staging platform was prepared at the coronal aspect of the fractured instrument. Then, a trepan bur was used to expose 1-1.5 mm of the fragmented instrument, and a microtube device was used to withdraw the fragment. Microcomputed tomographic (micro-CT) imaging was used to evaluate the geometric changes in the root canal and dentin. The time required for fractured instrument removal in each sample was recorded, and the results were statistically analyzed with a paired t test.

Results: The trepan bur/microtube technique exhibited a success rate of 76.47%, and the average fractured instrument removal time was 8.55 ± 5.81 min. The changes in canal volume and dentin volume from the coronal end of the fractured instrument to 1.5 mm apical to the end were significantly greater than those from the cementoenamel junction (CEJ) to the coronal end of the fractured instrument during fractured instrument removal (P < 0.0001).

Conclusions: The study showed that the trepan bur/microtube technique had a significant impact on geometric changes in the root canal and dentin from the coronal end of the fractured instrument to 1.5 mm apical to the end.

Clinical Relevance: These findings suggest that the trepan bur/microtube technique may be an optional method for fractured instrument removal from relatively straight canals.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-019-03032-6DOI Listing

Publication Analysis

Top Keywords

fractured instrument
24
trepan bur/microtube
12
bur/microtube technique
12
instrument removal
12
fractured
9
microcomputed tomographic
8
removal fractured
8
fractured instruments
8
dental operating
8
operating microscope
8

Similar Publications

The mechanical properties of music wire are contingent upon its microstructure, which in turn influences its applications in music. Chinese stringed instruments necessitate exacting standards for comprehensive performance indexes, particularly with regard to the strength, resilience, and rigidity of the musical steel wires, which differ from the Western approach to musical wire. In this study, SWP-B music wire was selected for investigation through metal heat treatment, which was employed to regulate its microstructure characteristics.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

A basicervical femoral fracture is a relatively uncommon type of proximal femoral fracture. However, as the proportion of proximal femoral fractures rises in conjunction with the aging of society, the absolute number of patients with basicervical femoral fractures is also increasing. Nevertheless, the optimal surgical methods for the treatment of basicervical femoral fractures remain a topic of debate.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Valgus-impacted femoral neck fractures (OTA 31B1.1 and 31B1.2) are considered stable fractures with favorable outcomes compared to displaced fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!