Background: Both contact force monitoring (CFM) and unipolar signal modification (USM) are guides for ablation, which improve the efficacy of pulmonary vein isolation of atrial fibrillation. We sought to compare the outcomes of atrial fibrillation ablation guided by CFM or USM.

Methods: A total of 136 patients with paroxysmal atrial fibrillation underwent a circumferential pulmonary vein isolation using CF sensing ablation catheters and were randomly assigned to undergo catheter ablation guided by either CFM (CFM-guided group: n=70) or USM (USM-guided group: n=66). In the USM-guided group, each radiofrequency application lasted until the development of completely positive unipolar electrograms. In the CFM-guided group, a CF of 20 g (range, 10-30 g) and minimum force-time integral of 400 g were the targets for each radiofrequency application. The primary end point was freedom from any atrial tachyarrhythmia recurrence without antiarrhythmic drugs at 12-months of follow-up.

Results: The cumulative freedom from recurrences at 12-months was 85% in the USM-guided group and 70% in the CFM-guided group (P=0.031). The incidence of time-dependent and ATP-provoked early electrical reconnections between the left atrium and PVs, procedural time, fluoroscopic time, and average force-time integral, did not significantly differ between the 2 groups. The radiofrequency time for the pulmonary vein isolation was shorter in the USM-guided group than CFM-guided group but was not statistically significant (P=0.077).

Conclusions: USM was superior to CFM as an end point for radiofrequency energy deliveries during the pulmonary vein isolation in patients with paroxysmal atrial fibrillation in terms of the 12-month recurrence-free rate.

Clinical Trial Registration: URL: https://www.umin.ac.jp/ctr/index.htm. Unique identifier: UMIN000021127.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.119.007311DOI Listing

Publication Analysis

Top Keywords

atrial fibrillation
20
pulmonary vein
16
vein isolation
16
cfm-guided group
16
usm-guided group
16
contact force
8
force monitoring
8
unipolar signal
8
signal modification
8
catheter ablation
8

Similar Publications

Prognostic impact of one-year permanent pacemaker implantation after mitral valve surgery with the Cox-maze procedure.

Eur J Cardiothorac Surg

January 2025

Department of Thoracic and Cardiovascular Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea.

Objectives: This study aimed to evaluate the prognostic impact of permanent pacemaker (PPM) implantation within the first year after mitral valve (MV) surgery combined with the Cox-maze procedure, focusing on long-term outcomes, including overall mortality, infective endocarditis (IE), and ischaemic stroke.

Methods: We conducted a retrospective cohort study using data from the National Health Insurance Service (NHIS) in South Korea, identifying 10,127 patients who underwent MV surgery with the Cox-maze procedure between 2005 and 2020. Patients were classified into the PPM and non-PPM groups based on PPM implantation within one year postoperatively.

View Article and Find Full Text PDF

Multi-diagnostic chest-worn patch to detect obstructive sleep apnea and cardiac arrhythmias.

J Clin Sleep Med

January 2025

Division of Sleep Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.

Study Objectives: Evaluate the performance of the SANSA device to simultaneously assess obstructive sleep apnea (OSA) and cardiac arrhythmias.

Methods: Participants suspected or known to have OSA underwent polysomnography (PSG) while wearing SANSA. SANSA's algorithm was trained using 86 records and tested on 67 to evaluate training bias.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!