A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cortical and Trabecular Bone Fracture Characterisation in the Vertebral Body Using Acoustic Emission. | LitMetric

The ability to rapidly detect localised fractures of cortical and/or trabecular bone sustained by the vertebral body would enhance the analysis of vertebral fracture initiation and propagation during dynamic loading. In this study, high rate axial compression tests were performed on twenty sets of three-vertebra lumbar spine specimens. Acoustic Emission (AE) sensor measurements of sound wave pressure were used to classify isolated trabecular fractures and severe compressive fractures of vertebral body cortical and trabecular bone. Fracture detection using standard AE parameters was compared to that of traditional mechanical parameters obtained from load cell and displacement readings. Results indicated that the AE parameters achieved slightly enhanced classification of isolated trabecular fractures, whereas the mechanical parameters better identified combined fractures of cortical and trabecular bone. These findings demonstrate that AE may be used to promptly and accurately identify localised fractures of trabecular bone, whereas more extensive fractures of the vertebral body are best identified by load cell readings due to the considerable loss in compressive resistance. The discrimination thresholds corresponding to the AE parameters were based on calibrated measurements of AE wave pressure and may ultimately be used to examine the onset and progression of vertebral fracture in other loading scenarios.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-019-02316-yDOI Listing

Publication Analysis

Top Keywords

trabecular bone
20
vertebral body
16
cortical trabecular
12
bone fracture
8
acoustic emission
8
localised fractures
8
fractures cortical
8
vertebral fracture
8
wave pressure
8
isolated trabecular
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!