A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Needle aspiration for treating iatrogenic pneumothorax after cardiac electronic device implantation: a pilot study. | LitMetric

Purpose: Pneumothorax (PTX) following cardiac implantable electronic device procedures is traditionally treated with chest tube drainage (CTD). We hypothesized that, in a subset of patients, the less invasive needle aspiration (NA) may also be effective. We compared the strategy of primary NA with that of primary CTD in a single-center observational study.

Methods: Of the 970 procedures with subclavian venous access between January 2016 and June 2018, 23 patients had PTX requiring intervention. Beginning with March 2017, the traditional primary CTD (9 cases) has been replaced by the "NA first" strategy (14 patients). Outcome measures were procedural success rate and duration of hospitalization evaluated both as time to event (log-rank test) and as a discrete variable (Wilcoxon-Mann-Whitney test).

Results: Needle aspiration was successful in 8/14 (57.1%) of the cases (95% CI 28.9-82.3%), whereas PTX resolved in all patients after CTD was 9/9 (100%, 95% CI 66.4-100.0%, p = 0.0481). Regarding length of hospital stay, intention to treat time to event analysis showed no difference between the two approaches (p = 0.73). Also, the median difference was not statistically significant (- 2.0 days, p = 0.17). In contrast, per protocol evaluation revealed reduced risk of prolonged hospitalization for NA patients (p = 0.0025) with a median difference of - 4.0 days (p = 0.0012). Failure of NA did not result in a meaningful delay in discharge timing as median difference was 1.5 days (p = 0.28).

Conclusions: Our data suggest that in a number of patients iatrogenic PTX may be successfully treated with NA resulting in shorter hospitalization without the risk of meaningful discharge delay in unsuccessful cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093351PMC
http://dx.doi.org/10.1007/s10840-019-00596-xDOI Listing

Publication Analysis

Top Keywords

needle aspiration
12
median difference
12
electronic device
8
primary ctd
8
time event
8
patients
6
aspiration treating
4
treating iatrogenic
4
iatrogenic pneumothorax
4
pneumothorax cardiac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!