A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 998
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3138
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nuclear magnetic resonance analysis of a chemically cross-linked ferrous-methylthymol blue-polyvinyl alcohol radiochromic gel dosimeter. | LitMetric

Nuclear magnetic resonance analysis of a chemically cross-linked ferrous-methylthymol blue-polyvinyl alcohol radiochromic gel dosimeter.

Appl Radiat Isot

Doctoral School of Physics, ELTE Eötvös Loránd University, Budapest, Hungary and Radiation Biophysics Group, MTA Centre for Energy Research, Budapest, 1518, Hungary.

Published: November 2019

A new formulation of hydrogel dosimeter consisting of ferrous-methylthymol blue (MTB)-polyvinyl alcohol (PVA) cross-linked chemically with glutaraldehyde (GTA) was studied and evaluated by nuclear magnetic resonance analysis by means of the R spin-spin relaxation rate. Previous optical studies of this transparent solid chemically cross-linked gel showed important dosimetric features in terms of sensitivity, auto-oxidation rate, and diffusion. This study shows that the MTB-PVA-GTA dosimeter has a reproducible linear dose response up to 40 Gy. For the optimum formulation of 0.1 mM MTB, 2.5% PVA, and 26.6 mM GTA, the measured R sensitivity was higher than that of traditional natural matrix-containing gels (MTB-gelatin) and all other reported PVA gel-based radiochromic dosimeters with MTB, xylenol orange (XO), or GTA (MTB-PVA, XO-PVA, XO-PVA-GTA). Additionally, the auto-oxidation rate was approximately ten times lower than that of the Fricke-MTB-gelatin system, which is consistent with the spectrophotometry results. The results of the independent experimental spectrophotometry and nuclear magnetic resonance analyses indicate that the transparent cross-linked dosimeter has good and consistent dosimetric features.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2019.108812DOI Listing

Publication Analysis

Top Keywords

nuclear magnetic
12
magnetic resonance
12
resonance analysis
8
chemically cross-linked
8
dosimetric features
8
auto-oxidation rate
8
analysis chemically
4
cross-linked
4
cross-linked ferrous-methylthymol
4
ferrous-methylthymol blue-polyvinyl
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!