A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Generation of magnifying endoscopic images of gastric neoplasms based on an all-in-focus algorithm. | LitMetric

Background And Aim: Magnifying endoscopy is useful for diagnosis of early gastrointestinal neoplasms by visualizing microvascular (MV) and microsurface (MS) structures of the mucosa when combined with image-enhanced endoscopy. However, precise control of the endoscope is needed because the depth of focus is narrow and the target may move. These problems may be overcome by the all-in-focus (AIF) technique, which was developed in the engineering field. The aim of the study was to evaluate magnifying endoscopic image with AIF algorithm.

Methods: Twenty gastric neoplasms were examined. Images were acquired at 80× magnification and converted to endoscopic images with an AIF algorithm (EI-AIF). The focus area and MV and MS patterns in the original image and the EI-AIF were compared on a 5-point Likert scale, where 5 indicates that the EI-AIF was superior. Intraclass correlation coefficients (ICCs) were used to assess the inter-evaluator reliability. An image quality measurement value was calculated for each image as an indicator of the degree of focus.

Results: The scores for focus area, MV, and MS were 4.78 ± 0.45 (ICC = 0.63), 4.12 ± 0.76 (ICC = 0.70), and 4.72 ± 0.52 (ICC = 0.45), respectively, with the EI-AIF significantly superior for all three items (P < 0.05 by Student's t-test). ICCs for the focus area and MV were > 0.60, indicating strong inter-evaluator reliability. Image quality measurement was higher for the EI-AIF compared with the original image in every case.

Conclusions: Endoscopic observation with AIF algorithm gives a better image quality that allows easier evaluation of MV and MS patterns. This technique may resolve the difficulties with magnifying endoscopic observation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jgh.14792DOI Listing

Publication Analysis

Top Keywords

magnifying endoscopic
12
focus area
12
image quality
12
endoscopic images
8
gastric neoplasms
8
aif algorithm
8
original image
8
ei-aif compared
8
ei-aif superior
8
inter-evaluator reliability
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!