The development of a low-flow vascular prosthesis is a very topical issue. The authors present a pathway for the development of a prosthesis with optimal properties based on the idea of mimicking the characteristics of a biological model (saphenous vein graft) and programming these properties in the model of the prosthetic substitute. The vascular prosthesis presented consists of three layers - a non-absorbable scaffold representing vascular “media”, and two absorbable collagen layers - pseudointima and pseudoadventitia. The basic methods of physical testing are presented - the single axis stretch test and inflation-extension test, as well as other procedures that affect the final properties. These include collagen curing, antithrombotic treatment of the inner layer and the use of sterilization methods. The designed new graft was successfully implanted in an ovine model.

Download full-text PDF

Source

Publication Analysis

Top Keywords

vascular prosthesis
8
development vascular
4
vascular substitutes
4
substitutes low-flow
4
low-flow peripheral
4
peripheral bypass
4
bypass grafting
4
grafting review
4
review development
4
development a low-flow
4

Similar Publications

Reintervention after aortic root replacement with allograft, xenograft, and stented bioprosthetic valves.

Cardiovasc Revasc Med

December 2024

Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA, United States of America; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA, United States of America. Electronic address:

Background: There has been a significant increase in the utilization of non-mechanical valves in the aortic position over time. However, details in reinterventions after aortic root replacement (ARR) with non-mechanical prosthesis were limited in the literature, despite the potential importance of reinterventions in the lifetime management of aortic valve disease.

Methods: This is a single-center retrospective study, identifying all patients who underwent ARR with allograft, xenografts, and stented bioprosthetic valved conduit from 2010 to 2020.

View Article and Find Full Text PDF

Importance: It remains unknown whether outcomes of the Placement of Aortic Transcatheter Valves 3 (PARTNER 3) and Evolut Low Risk trials are comparable with surgical outcomes in nontrial settings, considering the added risk of concomitant cardiac operations.

Objective: To compare 30-day mortality and stroke incidences of patients in the surgical aortic valve replacement (SAVR) arm of low-risk trials with those of similar patients in the US Society of Thoracic Surgeons Adult Cardiac Surgery Database (STS ACSD).

Design, Setting, And Participants: A cross-sectional sampling study was conducted of adults in the STS ACSD with severe aortic stenosis at low surgical risk for AVR who underwent SAVR during the years low-risk AVR trials (PARTNER 3 and Evolut Low Risk) were enrolling (calendar years 2016-2018).

View Article and Find Full Text PDF

This case report evaluates current diagnostic and treatment approaches for intrapelvic acetabular migration, focusing on the rare but serious complication of acute limb ischemia following hip arthroplasty. A 67-year-old female with a history of total hip arthroplasty 10 years ago presented with acute limb ischemia after experiencing a traumatic event 72 hours prior, which had caused displacement of her hip prosthesis. Notably, she had a history of a traumatic event two years earlier for which she had been advised to undergo surgical correction, which she had refused.

View Article and Find Full Text PDF

Background: Coarctation of the aorta (CoA) in adults is rare. usually combined with dilatation of the ascending aorta. Further disease progression complicated by hematoma or dissection of the ascending aorta is even more complicated and dangerous.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation complexity score.

Open Heart

January 2025

Department of Cardiology, Leeds General Infirmary, Leeds, UK

Background: Increasing demand for transcatheter aortic valve implantation (TAVI) places greater emphasis on the efficiency of pathways and services. A significant limitation to increasing TAVI capacity is the availability of cardiac catheterisation laboratory time. We have developed a novel complexity scoring system (TAVI ComplEXity; TEX score) which can aid in planning lists with appropriate case selection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?