Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A simple and inexpensive approach for determination of various antimicrobial drugs using a purpose-made compact capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (CD) is reported. The objective of the work is to propose an affordable and easily-implemented tool for quality control and detection of counterfeiting of antibiotic formulations in resource constrained developing countries. The design of the purpose-made CE-CD system was improved according to the feedback from over 10 years of use of our previous instrument. CE-CD methods were for the first time developed to analyze β-lactam-based antibiotics commonly used in Vietnam, including single- β-lactam antibiotics (i.e. Cephalexin, Cefotaxime Sodium, Cefixime and Sulbactam) as well as β-lactams co-formulated with Sulbactam (i.e. Amoxicillin, Ampicillin, Cefoperazone and Sulbactam). Single β-lactam antibiotics were analyzed using a background electrolyte (BGE) composed of Tris/Ace (10 mM, pH 7.8) whereas β-lactam - Sulbactam combinations were simultaneously separated using a BGE containing Tris/Ace (10 mM, pH 7.5). The best achieved detection limits were 2.0 mg/L and 1.0 mg/L for these two groups, respectively. Good agreement between results obtained from CE-CD and standard confirmation methods (LCMS) was achieved, with a coefficient of determination, r, of 0.9991. The applicability of the developed CE-CD method was demonstrated for quality control of 24 β-lactam-based antimicrobial drugs available in Vietnam.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2019.07.010 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!