A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Deformation of acetabular press-fit cups: Influence of design and surgical factors. | LitMetric

Background: Deformation of acetabular cups when press-fitted into an undersized cavity is inevitable due to the inhomogeneous stiffness of acetabular bone. Thinner cups or screw holes might increase the risk of high cup deformation. The aim of this study was to examine the influence of cup design and liner assembly on the deformation response during cup implantation.

Methods: Acetabular cups with different designs were implanted into polyurethane foam models simulating the anatomical situation with nominal press-fits of 1mm and without nominal press-fits (line-to-line). Deformations were determined using a tactile coordinate measuring machine. A 3D laser scanner was used to determine the contact conditions at the cup-cavity interface. Polyethylene and ceramic liners were assembled to the implanted cups and the influence of the insertion on the deformation response evaluated. Fixation strength of the cups was determined by push-out testing.

Findings: Cup deformation increased with smaller wall thickness (P < 0.037) and screw holes (P < 0.001). Insertion of ceramic liners reduced the deformation (P < 0.001), whereas polyethylene liners adapted to the deformation of the implanted cups (P > 0.999). Thin-walled cups exhibited a higher fixation strength for similar implantation forces (P = 0.011).

Interpretation: Thin-walled cups achieved higher fixation strengths and might be more bone-preserving. However, in combination with screw holes and high press-fit levels, wall thickness should be considered carefully to avoid excessive cup deformations leading to potential complications during liner assembly. Line-to-line insertion of thin-walled cups should be accompanied with a rough surface coating to minimize the loss of fixation strength due to the low press-fit fixation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2019.07.014DOI Listing

Publication Analysis

Top Keywords

deformation acetabular
8
cups influence
8
acetabular cups
8
cup deformation
8
deformation response
8
nominal press-fits
8
deformation
6
cups
6
acetabular press-fit
4