Comparison of apical irrigant solution extrusion among conventional and laser-activated endodontic irrigation.

Lasers Med Sci

Department of Endodontics and Restaurative Dentistry, School of Dentistry, University of Rijeka, Braće Branchetta 20, 51 000, Rijeka, Croatia.

Published: February 2020

The aim of this study was to determine the amount of extruded endodontic irrigant among needle-syringe irrigation (NSI) and laser-activated irrigation (LAI) regimens. Twenty extracted maxillary central incisors were prepared utilizing GT professional rotary files (size 40, taper 0.06). Irrigation was performed with two 27 G irrigation needles (notched open ended (ON) and single side vented (SV)) each at two different irrigant volumetric flow rates (VFR)-0.05 ml/s (3 ml/min) and 0.10 ml/s (6 ml/min). LAI was performed with Er:YAG (erbium-doped yttrium aluminum garnet) using different fiber types (X-Pulse-14/400 cylindrical tip, Preciso- 14/300 flat cylindrical tip, PIPS- 14/400 quartz tapered tip). The Er:YAG laser with a wavelength of 2940 nm (Lightwalker AT, Fotona, Ljubljana, Slovenia) was used according to the following protocol: 10 mJ per pulse, 15 Hz, pulse duration 50 μs. Irrigation time was 60 s for all protocols. Precision syringe pump (PSP) maintained constant irrigant volumetric flow rate. Apically extruded irrigant was collected and net weighed for each protocol (N = 10). Data were analyzed by t tests and Kruskal-Wallis. All LAI regimens had statistically significant lower irrigant extrusion compared with NSI except for the SV 27 G needle used with 0.05 ml/s VFR when compared with the Preciso fiber tip (p = 0,230). The largest amount of extruded irrigant was with the ON 27 G needle at the 0.10 ml/s VFR, while the smallest was after LAI with PIPS fiber tip. The lower quantity of apically extruded irrigant during LAI (X-Pulse and PIPS) points out a safer endodontic irrigation method compared with conventional irrigations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10103-019-02846-wDOI Listing

Publication Analysis

Top Keywords

extruded irrigant
12
irrigant
8
endodontic irrigation
8
amount extruded
8
lai regimens
8
irrigant volumetric
8
volumetric flow
8
apically extruded
8
27 g needle
8
irrigation
7

Similar Publications

Objective: This study aims to quantitatively compare the effects of standard needle irrigation (SNI), passive ultrasonic irrigation (PUI), EDDY, photon-initiated photoacoustic streaming (PIPS), and shock wave-enhanced emission photoacoustic streaming (SWEEPS) on the apical extrusion of irrigation solutions in teeth with severe canal curvature.

Materials And Methods: Seventy-five teeth with a single root and canal, and curvature angles ranging from 20° to 40°, were selected for this study. Root canal curvatures were measured from buccolingual and mesiodistal radiographs using ImageJ software (version 1.

View Article and Find Full Text PDF

Aims And Background: Failure of the endodontic treatment might be due to various reasons like zipping, apical blockade, ledging, debris extrusion, etc. Apical debris extrusion in primary teeth is of major concern as it does not have a proper well-developed apex, that is, mature apex. This study aims to compare and evaluate the apical debris extrusion in primary molars using three different pediatric rotary file system.

View Article and Find Full Text PDF

This in vitro research assessed the influence of the instrument kinematics (rotary and reciprocating) and the apical preparation limit on the root canal disinfection and apical bacterial extrusion. After 21 days of Enterococcus faecalis biofilm formation in 72 mesial root canals of mandibular molars, the root canals were distributed into 2 groups (n = 36) according to the systems used for preparation: ProDesign S and Reciproc. The groups were redistributed according to the limit of apical preparation (n = 11): (a) 1 mm up to the apical foramen (TL-1); (b) at the apical foramen (TL = 0); (c) 1 mm beyond the apical foramen (TL + 1).

View Article and Find Full Text PDF

Background: Periapical extrusion of debris for root retreatment will effectively improve the posttreatment inflammation and pain. The aim of this study was to investigate the extruded debris for root retreatment using XP shaper and ProTaper files.

Materials And Methods: In his experimental laboratory study, 40 extracted human maxillary molars were used in this laboratory study.

View Article and Find Full Text PDF

Complete talar extrusion is a rare injury that is typically caused by high-energy impact. Treatment for a completely extruded talus is limited and has variable outcomes and complications. Tibiocalcaneal arthrodesis is one of the best treatments for restoring stability and reducing pain in the affected limb.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!