A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Risk factors for distal migration of biliary plastic stents and related duodenal injury. | LitMetric

Risk factors for distal migration of biliary plastic stents and related duodenal injury.

Surg Endosc

Department of Gastroenterology, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, China.

Published: April 2020

Background: The risk factors of duodenal injury from distal migrated biliary plastic stents remain uncertain. The aim of this study was to determine the risk factors of distal migration and its related duodenal injury in patients who underwent placement of a single biliary plastic stent for biliary strictures.

Methods: We retrospectively reviewed all patients with biliary strictures who underwent endoscopic placement of a single biliary plastic stent from January 2006 to October 2017.

Results: Two hundred forty-eight patients with 402 endoscopic retrograde cholangiopancreatography procedures were included. The incidence of distal migration was 6.2%. The frequency of duodenal injury was 2.2% in all cases and 36% in cases with distal migration. Benign biliary strictures (BBS), length of the stent above the proximal end of the stricture (> 2 cm), and duration of stent retention (< 3 months) were independently associated with distal migration (p = 0.018, p = 0.009, and p = 0.016, respectively). Duodenal injury occurred more commonly in cases with larger angle (≥ 30°) between the distal end of the stent and the centerline of the patient's body (p = 0.018) or in cases with stent retention < 3 months (p = 0.031).

Conclusions: The risk factors of distal migration are BBS and the length of the stent above the proximal end of the stricture. The risk factor of duodenal injury due to distal migration is large angle (≥ 30°) between the distal end of the stent and the centerline of the patient's body. Distal migration and related duodenal injury are more likely to present during the early period after biliary stenting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093356PMC
http://dx.doi.org/10.1007/s00464-019-06957-xDOI Listing

Publication Analysis

Top Keywords

distal migration
16
biliary plastic
16
duodenal injury
16
risk factors
12
factors distal
8
plastic stents
8
placement single
8
single biliary
8
plastic stent
8
biliary strictures
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!