A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Portable stir membrane device for on-site environmental sampling and extraction. | LitMetric

Portable stir membrane device for on-site environmental sampling and extraction.

J Chromatogr A

Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain. Electronic address:

Published: November 2019

A portable device that integrates sampling and extraction is proposed in this work. The unit is fabricated using commercial and standardized elements which guarantees the construction reproducibility. Also, it is simple to be mounted and on-site deployed making possible the multi-site sampling. The device uses a commercial nylon membrane as extraction phase for the isolation of the target compounds, but it can be adapted to other flat sorptive phases thus expanding the applicability. Once mounted, the unit is stirred into the sample by means of a portable drill enhancing in that way the diffusion of the target analyte towards the extraction phase. The hydrodynamic behavior and the design have been optimized and the device has been finally used for the extraction benzophenones from swimming pool samples. These endocrine disruptive compounds are determined by liquid chromatography tandem mass spectrometry (LC-MS/MS) at concentrations as low as 0.1 μg/L with precision, expressed as relative standard deviation, better than 9.9%. The accuracy, calculated as relative recovery, was in the range from 74 to 111 % thus being considered appropriate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2019.07.013DOI Listing

Publication Analysis

Top Keywords

sampling extraction
8
extraction phase
8
extraction
5
portable stir
4
stir membrane
4
device
4
membrane device
4
device on-site
4
on-site environmental
4
environmental sampling
4