Objective: To examine the biomechanical stress distribution at the upper instrumented vertebra (UIV) according to unicortical- and bicortical purchase model by finite element analysis (FEA).

Methods: A T8 to Sacrum with implant finite element model was developed and validated. The pedicle screws were unicortically or bicortically inserted from T10 to L5, and each model was compared and the von Mises (VM) yield stress of T10 was calculated. According to the motion (flexion, extension, lateral bending, and axial rotation) of spine, boundary condition values were set as 15°, 15°, 10°, 4°.

Results: Although the 2 stress values did not show a significant difference between the unicortical- and bicortical purchase models in the flexion and extension, bicortical purchase model showed a larger stress distribution. However, the asymmetric behavior was significantly greater in the case of lateral bending (0.802 MPa vs. 0.489 MPa) and the rotation (5.545 MPa vs. 4.905 MPa). The greater stress was observed on the spinal body surface abutting the implanted screw. Although the maximum stress was observed around the implanted screw in the bicortical purchase model under axial loading, the VM stress of both models was not significantly different.

Conclusion: Bicortical purchase model showed a larger stress distribution than the unicortical model, especially in the case of lateral bending and the rotation behavior. Our biomechanical simulation by FEA indicates that bicortical fixation at UIV can be a risk factor for early UIV compression fracture after adult spinal deformity surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7338956PMC
http://dx.doi.org/10.14245/ns.1938100.050DOI Listing

Publication Analysis

Top Keywords

bicortical purchase
20
purchase model
16
finite element
12
stress distribution
12
lateral bending
12
upper instrumented
8
instrumented vertebra
8
vertebra uiv
8
fracture adult
8
adult spinal
8

Similar Publications

Purpose: Good initial fixation of glenoid component for reverse total shoulder arthroplasty (RTSA) relies on component placement and screw purchase in the scapula bone. This is especially difficult in an Asian population with small glenoid geometry. Optimal glenoid component roll angle and screw angulation to achieve the longest screws for best fixation has not been defined in the current literature.

View Article and Find Full Text PDF

Background: Sacral screw loosening is a typical complication after internal fixation surgery through the vertebral arch system. Bicortical fixation can successfully prevent screw loosening, and how improving the rate of bicortical fixation is a challenging clinical investigation.

Objective: To investigate the feasibility of improving the double corticality of sacral screws and the optimal fixation depth to achieve double cortical fixation by combining the torque measurement method with bare hands.

View Article and Find Full Text PDF

Background: Bicortical suspension device (BCSD) fixation treats proximal tibiofibular joint (PTFJ) instability in both the anterolateral and posteromedial directions. However, biomechanical data are lacking as to whether this technique restores the native stability and strength of the joint.

Purpose: To test (1) if BCSD fixation restores the native stability and strength and (2) if using 2 devices is needed.

View Article and Find Full Text PDF

Objective: The purpose of this study is to highlight our technique for freehand placement of juxtapedicular screws along with intraoperative computed tomography (CT) and radiographic results.

Methods: Consecutive patients with adult idiopathic scoliosis undergoing primary surgery by the senior author were identified. All type D (absent/slit like channel) pedicles were identified on preoperative CT.

View Article and Find Full Text PDF

Background: Odontoidectomy may pose some risks for O-C1 and/or C1-C2 instability, with previous authors reporting techniques for endonasal C1-C2 fusion. However, no technique for endonasal O-C1 fusion currently exists. We sought to describe the feasibility of endonasal anterior C1 (AC1) screw placement for endonasal O-C1 fusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!