A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospective Investigation of the Performance of 2 Gamma-Hydroxybutyric Acid Tests: DrugCheck GHB Single Test and Viva-E GHB Immunoassay. | LitMetric

AI Article Synopsis

  • The study evaluated the effectiveness of two urine tests for detecting GHB in emergency department patients, focusing on a new test called DrugCheck GHB Single Test and the Viva-E immunoassay.
  • In a sample of 375 patients with potential drug intoxication, the DrugCheck test showed a specificity of 90% and sensitivity of 72.9%, improving with a higher cutoff value.
  • The Viva-E immunoassay demonstrated significantly higher accuracy, with a specificity of 99.4% and sensitivity of 93.5%, especially when excluding samples with high ethanol levels.
  • Overall, while the DrugCheck test was reliable, the Viva-E immunoassay provided superior performance in detecting GHB in urine samples.

Article Abstract

Background: Gamma-hydroxybutyric acid (GHB) is a recreational drug with central nervous system depressing effects that is often abused. A urine GHB point-of-care test can be of great diagnostic value. The objective of this prospective study was to determine the performance of the new DrugCheck GHB Single Test and the Viva-E GHB immunoassay for urine samples in emergency department patients.

Methods: Patients presented to the emergency department of the OLVG hospital in Amsterdam with a Glasgow Coma Scale score <15 and potential drug of abuse intoxication were included in the study. Between June 2016 and October 2017, 375 patients were included. Using the DrugCheck GHB Single Test (Express Diagnostics Int'l, Blue Earth, MN) and the Viva-E GHB immunoassay (Siemens Healthineers, The Hague, the Netherlands), patients' urine samples were tested for GHB (cutoff for a positive result, 10 or 50 mcg/mL GHB). To ensure quality, the results obtained were compared with those generated using a validated gas chromatography method. The tests were considered reliable if specificity and sensitivity were both >90%. Possible cross-reactivity with ethanol was investigated by analyzing ethanol concentrations in patients' samples.

Results: Seventy percentage of the included patients was men, and the median age was 34 years old. The DrugCheck GHB Single Test's specificity and sensitivity were 90.0% and 72.9%, respectively, and using 50 mcg/mL as a cutoff value, its specificity and sensitivity improved to 96.7% and 75.0%, respectively. Serum and urine ethanol levels in the false-positive group were significantly higher compared with those in the true-negative group. The specificity and sensitivity of the Viva-E GHB immunoassay (cutoff value of 50 mcg/mL and excluding samples with ethanol levels ≥2.0 g/L) were 99.4% and 93.5%, respectively.

Conclusions: The DrugCheck GHB Single Test's specificity was sufficient, whereas its sensitivity was poor, making it unsuitable for use at point-of-care. Contrarily, using 50 mcg/mL as the cutoff value and excluding samples with ethanol levels ≥2.0 g/L, the Viva-E GHB immunoassay showed acceptable results to detect clinically relevant GHB intoxications.

Download full-text PDF

Source
http://dx.doi.org/10.1097/FTD.0000000000000677DOI Listing

Publication Analysis

Top Keywords

drugcheck ghb
16
ghb single
16
viva-e ghb
16
ghb immunoassay
16
specificity sensitivity
12
ethanol levels
12
ghb
11
gamma-hydroxybutyric acid
8
single test
8
test viva-e
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!