[Transmastoidslotted labyrinthotomy approach cochlear implantation with customized electrode for patients with common cavity deformity].

Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi

Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China.

Published: July 2019

To discuss the benefit of using transmastoid slotted labyrinthotomy approach (TSLA) and customized electrode for common cavity deformity (CCD) patients, and to evaluate the audiological outcomes. A retrospective analysis of the intraoperative monitoring data and postoperative auditory outcomes of 10 CCD cases who received cochlear implantation in Beijing Tongren Hospital,Capital Medical University from April 2016 to December 2017, was conducted using TSLA and customized electrod as a test group.At the same time, 10 cases of age and gender matched children with severe or severe sensorineural hearing loss and normal inner ear structures were recorded as a control group. Four questionnaires were collected from the two groupspre-operative, 6 months and 1 year after start-up. The Wilcoxon signed rank sum test was used to compare the scores of different time points. Rank sum test of two independent samples was used to compare the scores between different groups. None of the patients exhibited CSF leakage or facial paralysis after operation. The average impedance of 8 CCD children in the experimental group was below 5 kΩ. The total extraction rate of auditory neural response telemetry (ART) of all stimulating electrodes was 55% (33/60), and the amplitude of the electricity induced complex action potential (ECAP) of electrodes at different positions ranged from 50.69 to 170.3 μV.The average surgical time of the TSLA group was 46.4 min, shorter than the traditional approach.There was significant difference between the scores of pre-operative, 6 months and 1 year after start-up for the TSLA group(categories of auditory performance,CAP: 2.0 (2.0,3.0) . 4.0 (3.8,4.0) , -3.109, 0.002; speech intelligibility rating,SIR: 2.0 (2.0,2.3) . 3.0 (2.8,4.0) , -2.952, 0.003; meaningful use of speech scale,MUSS: 4.0 (3.3,6.0) . 9.0 (6.0,11.8) , -3.421, 0.001; meaningful auditory integration scale, MAIS or infant-toddler and meaningful auditory integration scale, IT-MAIS: 5.5 (3.8,9.0) . 15.5 (10.8,18.5) , -3.522, 0.000 for the latter two).In addition, The scores of the TSLA group were significantly worse than the control group at 6 months and 1 year after start-up.The high-resolution CT scan showed good adhesion of the electrodes without displacementone week and one year after surgery. For CCD patients, TSLA and customized electrode is recommended due to lower surgical difficulty and post-operative risk, shortened surgical time; Intraoperative ART monitoring can be used to determine the integrity of the auditory pathway. Children with common cavity deformity have a longer period of auditory rehabilitation, and the individual differences in speech rehabilitation are significantly different, which is significantly worse than those with normal structure.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.issn.1673-0860.2019.07.002DOI Listing

Publication Analysis

Top Keywords

customized electrode
12
common cavity
12
tsla customized
12
months year
12
labyrinthotomy approach
8
cochlear implantation
8
cavity deformity
8
ccd patients
8
control group
8
year start-up
8

Similar Publications

Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time.

View Article and Find Full Text PDF

Reusable Biosensor for Easy RNA Detection from Unfiltered Saliva.

Sensors (Basel)

January 2025

Department of Clinical and Molecular Biochemistry, Pomeranian Medical University in Szczecin, 72 Powstańców Wlkp. Al., 70-111 Szczecin, Poland.

Biosensors are transforming point-of-care diagnostics by simplifying the detection process and enabling rapid, accurate testing. This study introduces a novel, reusable biosensor designed for direct viral RNA detection from unfiltered saliva, targeting SARS-CoV-2. Unlike conventional methods requiring filtration, our biosensor leverages a unique electrode design that prevents interference from saliva debris, allowing precise measurements.

View Article and Find Full Text PDF

Diabetes significantly increases the risk of serious health issues, including prolonged skin inflammation and delayed wound healing, owing to inferior glucose control and suppression of the immune system. Although traditional hydrogen (H2) therapy is slightly effective, its ability to tailor the release of H2 on the skin is limited. Accordingly, this study proposed a novel strategy for electrocatalytic H2 release under neutral conditions to promote wound healing in diabetic mice and rabbit.

View Article and Find Full Text PDF

Pulsed-Current Operation Enhances HO Production on a Boron-Doped Diamond Mesh Anode in a Zero-Gap PEM Electrolyzer.

ChemSusChem

January 2025

Department of Chemical Engineering, MESA+ Institute for Nanotechnology, Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB, Enschede, The, Netherlands.

A niobium (Nb) mesh electrode was coated with boron-doped diamond (BDD) using chemical vapor deposition in a custom-built hot-filament reactor. The BDD-functionalized mesh was tested in a zero-gap electrolysis configuration and evaluated for the anodic formation of HO by selective oxidation of water, including the analysis of the effects on Faradaic efficiency towards HO (FEH2O2) induced by pulsed electrolysis. A low electrolyte flow rate (V⋅) was found to result in a relatively high concentration of HO in single-pass electrolysis experiments.

View Article and Find Full Text PDF

A few decades ago, the technological boom revolutionized access to information, ushering in a new era of research possibilities. Electrochemical devices have recently emerged as a key scientific advancement utilizing electrochemistry principles to detect various chemical species. These versatile electrodes find applications in diverse fields, such as healthcare diagnostics and environmental monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!