Objectives: This study sought to evaluate the impact of prosthesis-patient mismatch (PPM) on the risk of early-term mortality after transcatheter aortic valve implantation (TAVI).
Methods: Databases (Medical Literature Analysis and Retrieval System Online [MEDLINE], Excerpta Medica dataBASE [EMBASE], Cochrane Controlled Trials Register [CENTRAL/CCTR], ClinicalTrials.gov, Scientific Electronic Library Online [SciELO], Latin American and Caribbean Literature on Health Sciences [LILACS], and Google Scholar) were searched for studies published until February 2019. PPM after TAVI was defined as moderate if the indexed effective orifice area (iEOA) was between 0.85 cm2/m2 and 0.65 cm2/m2 and as severe if iEOA ≤ 0.65 cm2/m2.
Results: The search yielded 1,092 studies for inclusion. Of these, 18 articles were analyzed, and their data extracted. The total number of patients included who underwent TAVI was 71,106. The incidence of PPM after TAVI was 36.3% (25,846 with PPM and 45,260 without PPM). One-year mortality was not increased in patients with any PPM (odds ratio [OR] 1.021, 95% confidence interval [CI] 0.979-1.065, P=0.338) neither in those with moderate PPM (OR 0.980, 95% CI 0.933-1.029, P=0.423). Severe PPM was separately associated with high risk (OR 1.109, 95% CI 1.041-1.181, P=0.001).
Conclusion: The presence of severe PPM after TAVI increased early-term mortality. Although moderate PPM seemed harmless, the findings of this study cannot not rule out the possibility of it being detrimental, since there are other registries that did not address this issue yet.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629219 | PMC |
http://dx.doi.org/10.21470/1678-9741-2019-0073 | DOI Listing |
Open Heart
January 2025
Department of Cardiology, Inserm U1096, Univ Rouen Normandie, CHU Rouen, Rouen, France
Introduction: Conductive disturbances requiring permanent pacemaker (PPM) implantation remain a major concern after transcatheter aortic valve implantation (TAVI).
Aims: To assess the impact of aortic valve calcium score (AVCS) on conductive disturbances requiring PPM after TAVI.
Methods: All patients who underwent TAVI with accessible AVCS from the preprocedural CT scan report were included in this retrospective single-centre study.
JACC Cardiovasc Interv
December 2024
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.
Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.
Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.
Catheter Cardiovasc Interv
December 2024
Cardiology Department, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Background: The management of Transcatheter Aortic Valve Implantation (TAVI) patients with a small aortic annulus (SAA) postures a substantial challenge, increasing the risk of patient- prosthesis mismatch (PPM) and overall mortality.
Aims: This study aimed to compare the hemodynamic and clinical outcomes of transcatheter balloon-expandable valve (BEV) versus transcatheter self-expandable valve (SEV) in SAA.
Methods: We conducted propensity score matching (PSM) of severe AS patients with SAA who underwent trans-femoral TAVR and enrolled to the Israeli TAVR registry between the years 2008 and 2023.
JACC Asia
November 2024
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) is of greater concern in Asians, considering their relatively smaller annular sizes compared with Westerners. However, the prognostic significance of PPM in Asian populations has not been demonstrated.
Objectives: This study aimed to elucidate the prognostic value of PPM after TAVR in Asian patients.
Am J Cardiol
February 2025
Department of Cardiology, University Heart and Vascular Center Hamburg, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Germany; Department of Cardiology and Angiology, BG University Hospital Bergmannsheil, Ruhr University Bochum, Germany.
Prosthesis-patient mismatch (PPM) is a common phenomenon after transcatheter aortic valve implantation (TAVI), especially in patients with small aortic annuli. Whether factors during implantation, such as the implantation depth, have an impact on the occurrence of PPM is currently unclear. The objectives of our study were to (1) investigate the influence of procedure planning- and implantation-related factors on the occurrence of PPM and (2) evaluate the impact of PPM on long-term mortality after TAVI.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!