Introduction: The treatment of distal femur fractures in geriatric patients is challenging and has a high perioperative morbidity and mortality. Treatments have evolved significantly in the past decades. The aim of our study was to analyze local and systemic morbidity and mortality, as well as functional results in this frail cohort treated with distal femur locking plates.
Materials And Methods: In this single-institution case series, we retrospectively analyzed the data of patients aged 65 years and older with fractures of the distal femur between March 2013 and March 2018. All patients were operated with distal femur locking plates. Points of interest included perioperative morbidity, mortality, weight-bearing status, and care-dependency after hospital discharge.
Results: We assessed 49 patients (median age: 86.5 years) with 52 distal femur fractures (AO type A 77%, type C 15%, type B 8%). A total of 30 (58%) periprosthetic fractures with 4 (8%) interimplant femur fractures were documented. The perioperative morbidity was 64%, and the 3-month and 1-year mortality rates were 29% and 35%, respectively. The local complication rate was 6% with no documented implant failure. Of the patients who were living at home before the surgery, 62% required long-term accommodation in residential or nursing homes after dicharge from the hospital or short-term rehabilitation.
Conclusions: Geriatric patients with distal femur fractures face a high perioperative mortality. Osteosynthesis with distal femur locking plates is a reliable technique that can be used in various fracture patterns including periprosthetic and interimplant fractures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6607559 | PMC |
http://dx.doi.org/10.1177/2151459319860723 | DOI Listing |
Knee
January 2025
Department of Radiology, Keio University School of Medicine, Shinjuku, Tokyo, Japan.
Background: Long-leg alignment and joint line obliquity have traditionally been assessed using two-dimensional (2D) radiography, but the accuracy of this measurement has remained unclear. This study aimed to evaluate the accuracy of 2D measurements of lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) using upright three-dimensional (3D) computed tomography (CT).
Methods: This study involved 66 knees from 38 patients (34 women, four men) with knee osteoarthritis (OA), categorized by Kellgren-Lawrence (KL) grade.
Injury
January 2025
Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Denmark; Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital - University Hospital of Southern Denmark, Denmark; Department of Clinical Research, University of Southern Denmark, Denmark.
Background: Proximal femoral fractures has been associated with high mortality risk, while little is known about more distal lower extremity fractures. The aim was to report 30- and 365-days mortality in surgically treated lower extremity fractures in individuals above 65 years.
Materials And Methods: We extracted data from the Danish National Patient Register on all surgically treated lower extremity fracture in the period 1998-2017.
J Clin Med
January 2025
Department of Orthopaedic and Trauma Surgery, Institute of Medical Sciences, University of Opole, 45-040 Opole, Poland.
Developmental knee joint deformities are a common problem in pediatric orthopedics. Children with a valgus or varus deformity of the distal femur or the proximal tibia are commonly treated with hemiepiphysiodesis. Gait analysis in patients with lower limb deformities plays an important role in clinical practice.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFAnimals (Basel)
January 2025
Department of Biomedical Sciences, Ross University School of Veterinary Medicine, Basseterre P.O. Box 334, Saint Kitts and Nevis.
The paper presents a detailed gross anatomical description of the elements of the pelvic limb in the African green monkey and provides comparative and differential elements on pelvic limb monkey osteology. The osteometric investigation adds value to the gross morphological and radiological investigation, adjoining metric data to the gross descriptive data set. The main methodology used was the gross morphological investigation, doubled by regular osteometrical and radiographical assessments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!