Biomedical repositories such as the UK Biobank provide increasing access to prospectively collected cardiac imaging, however these data are unlabeled, which creates barriers to their use in supervised machine learning. We develop a weakly supervised deep learning model for classification of aortic valve malformations using up to 4,000 unlabeled cardiac MRI sequences. Instead of requiring highly curated training data, weak supervision relies on noisy heuristics defined by domain experts to programmatically generate large-scale, imperfect training labels. For aortic valve classification, models trained with imperfect labels substantially outperform a supervised model trained on hand-labeled MRIs. In an orthogonal validation experiment using health outcomes data, our model identifies individuals with a 1.8-fold increase in risk of a major adverse cardiac event. This work formalizes a deep learning baseline for aortic valve classification and outlines a general strategy for using weak supervision to train machine learning models using unlabeled medical images at scale.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629670PMC
http://dx.doi.org/10.1038/s41467-019-11012-3DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
weakly supervised
8
classification aortic
8
valve malformations
8
unlabeled cardiac
8
cardiac mri
8
mri sequences
8
machine learning
8
deep learning
8
weak supervision
8

Similar Publications

Background: Transcatheter aortic valve replacement (TAVR) has revolutionized the management of aortic stenosis and has become the standard of care across a broad spectrum of patients with aortic stenosis. However, it is still associated with high incidence of conduction abnormalities, particularly new left bundle branch block (LBBB). Management of these patients remains a challenge.

View Article and Find Full Text PDF

Anomalous Right Coronary Artery: Culprit or Innocent Bystander?

Case Rep Cardiol

January 2025

Department of Medicine, Division of Cardiology, University of Washington, Seattle, Washington, USA.

Anomalous aortic origin of a coronary artery is a rare congenital heart defect. The detection of anomalous coronary arteries is likely to increase with increased availability and application of cardiac computed tomography and magnetic resonance imaging. Once detected, the recommendation for surgical intervention on anomalous coronary arteries depends upon patient symptoms, the presence or absence of inducible ischemia on stress imaging, and high-risk anatomic features.

View Article and Find Full Text PDF

Heyde's syndrome is a clinical entity that combines aortic stenosis, gastrointestinal angiodysplasia, and an acquired von Willebrand factor disorder. This syndrome is characterized by the association between aortic stenosis and recurrent gastrointestinal bleeding episodes, typically linked to angiodysplasias. Effective treatment requires addressing the underlying condition, specifically aortic stenosis, which leads to the structural destruction of coagulation proteins, resulting in the acquired von Willebrand factor disorder and perpetuating the bleeding.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation (TAVI) has been established as an effective treatment modality in patients with severe aortic stenosis (AS) and the uptake of TAVI is rapidly growing in the Asia-Pacific region. However, there exist a heterogeneity in the management of aortic stenosis and the use of TAVI among countries in the region. Reasons for these differences include anatomic variations, disparity in healthcare resources and infrastructure, and the lack of consensus on the optimal management of AS in the Asia-Pacific region.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!