Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Lung function impairment is common in Congenital Diaphragmatic Hernia (CDH) survivors. The aim of this study was to evaluate, in children who underwent CDH surgical repair, mid and long-term consequences on respiratory impedance, investigating the impact of CDH on both resistance and reactance parameters, as well as bronchodilator response.Forced Oscillation Technique (FOT) parameters were collected from 12 patients (2-11 years). Resistance and reactance values at 8 Hz (Rrs8, Xrs8) and the area under the reactance curve (AX) were measured pre and post-salbutamol. Quantitative variables were compared using Mann-Whitney U test. Differences of categorical variables were evaluated using Fisher exact test. Statistically significant differences between measured and predicted values for Rrs8 (p = 0.04), Xrs8 (p = 0.02) and AX (p = 0.01) were found. When stratifying for age, significant difference between measured and predicted values was observed only in children < 5 years (n = 6) (Rrs8 p = 0.03, Xrs8 p = 0.001, AX p = 0.007). With respect to children 5 years (n = 6), the younger ones showed higher z-scores in Rrs8 (p = 0.015), Xrs8 (p = 0.002) and AX (p = 0.002) values. Since the z-score difference was greater than 0.5, it was considered a difference clinically relevant. No differences in bronchodilator response were recorded.In children with CDH an impairment of respiratory impedance measured by FOT is observed only in children aged less than 5 years.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6631876 | PMC |
http://dx.doi.org/10.1186/s13052-019-0670-6 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!