Objective: To assess glomerular filtration rate in the early phase of acute circulatory failure by measuring iohexol plasma clearance.

Design: Interventional prospective multicentric study.

Setting: Three French ICUs in tertiary teaching hospitals.

Patients: Patients with acute circulatory failure within 12 hours after ICU admission.

Interventions: IV administration of a nontoxic 5-mL dose of iohexol. Collection of nine arterial blood samples over 24 hours for iohexol plasma concentration measurements. Iohexol clearance calculation with a population pharmacokinetic model. Iohexol clearance was an estimation of the mean glomerular filtration rate over 24 hours.

Measurements And Main Results: Among 99 included patients, we could calculate iohexol clearance for 85. The median iohexol clearance was 31 mL/min (interquartile range, 16-44). According to iohexol clearance, 41 patients (48%) had severe hypofiltration (clearance, < 30 mL/min), 29 (34%) had moderate hypofiltration, and 10 (12%) had mild hypofiltration (clearance, 30-60 and 60-90 mL/min, respectively). Four patients (5%) had normal glomerular filtration rate, and only one (1%) showed hyperfiltration (clearance, > 130 mL/min). Urinary creatinine clearance underestimated renal impairment in one patient out of two; the bias of iohexol clearance toward 24-hour urinary creatinine clearance over the same period was -18.1 mL/min (limits of agreement, -73.5 to 37.4).

Conclusions: We demonstrated the feasibility of iohexol clearance measurement in unstable critically ill patients. Normal kidney function is exceptional during the early phase of acute circulatory failure. Glomerular filtration rate estimation by urinary creatinine clearance frequently fails to detect renal impairment. Hyperfiltration is very infrequent.

Download full-text PDF

Source
http://dx.doi.org/10.1097/CCM.0000000000003804DOI Listing

Publication Analysis

Top Keywords

iohexol clearance
28
acute circulatory
16
circulatory failure
16
glomerular filtration
16
filtration rate
16
clearance
13
urinary creatinine
12
creatinine clearance
12
iohexol
10
early phase
8

Similar Publications

Introduction: When GFR is measured (mGFR) using iohexol plasma clearance, results are reported both as a "non-indexed" (mL/min) and "body-surface area (BSA) indexed" to 1.73 m2. When these two values differ, there is no consensus as to which is preferable to use to determine suitability for living kidney donation (LKD).

View Article and Find Full Text PDF

Protamine protects against vancomycin-induced kidney injury.

Antimicrob Agents Chemother

January 2025

Department of Pharmacy Practice, College of Pharmacy, Midwestern University, Downers Grove, Illinois, USA.

Vancomycin causes kidney injury by accumulating in the proximal tubule, likely mediated by megalin uptake. Protamine is a putative megalin inhibitor that shares binding sites with heparin and is approved for the treatment of heparin overdose. We employed a well-characterized Sprague-Dawley rat model to assess kidney injury and function in animals that received vancomycin, protamine alone, or vancomycin plus protamine over 5 days.

View Article and Find Full Text PDF

Background: The estimation of glomerular filtration rate (eGFR) is essential in the early detection of diabetic nephropathy. We herein compare the performance of common eGFR formulas against a gold standard measurement of GFR in patients with diabetes mellitus.

Methods: GFR was measured in 93 patients with diabetes mellitus using iohexol clearance as the reference standard.

View Article and Find Full Text PDF

Background: Proenkephalin A 119-159 (penKid) is a novel blood biomarker for real-time assessment of kidney function and was found to be independently associated with worsening kidney function and mortality. A novel penKid-based estimated glomerular filtration rate equation (eGFR), outperforms current creatinine-based eGFR equations in predicting iohexol or iothalamate plasma clearance-based measured GFR. In this study, we aimed to evaluate the predictive value of penKid and eGFR for all-cause mortality in stable patients at high cardiovascular risk.

View Article and Find Full Text PDF

Evaluation of glomerular filtration rate estimation through plasma clearance of iohexol in seagulls (Larus michahellis).

BMC Vet Res

January 2025

Department of Veterinary Sciences, Veterinary Teaching Hospital "Mario Modenato", University of Pisa, via Livornese snc, San Piero a Grado, Pisa, Italy.

Background: Current endogenous indicators utilised in avian medicine are not sensitive enough to detect renal disease in its early stages. Alternative markers ought to be examined as a result. The aim is to investigate the accuracy of limited-sampling models for glomerular filtration rate (GFR) in adult seagulls using plasma clearance of iohexol (IOX).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!