Objective: This trial has the objective to investigate the incidence of mechanical ankle instability after the conservative treatment of first episode, severe ankle ligamentar lesions. This common lesion affects young, professional and physical active patients, causing important personal and economic consequences. There are difficulties related to adequate diagnosis and treatment for these lesions.
Method: 186 patients with severe ankle ligament lesions were included in this trial. They were randomized in two treatment options. In group A patients were treated using ankle long orthoosis, weight bearing allowed as confortable, pain care, ice, elevation with restricted joint mobilization for three weeks. After that they were maintained in short, functional orthosis (air cast), starting the reabilitation program. In group B patients were immobilized using a functional orthosis (air cast), following the same other sequences that patients in group A.
Results: We did not find significant differences in relation to the residual mechanical ankle instability between both groups. We did not find differences in the intensity of pain, but the functional evaluation using AOFAS score system showed better results in the functional treatment group.
Conclusion: The functional treatment (Group B) had better AOFAS score and few days off their professional activities, comparing with patients treated with rigid orthosis (Group A), without increased chance in developing ankle mechanical instability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6565899 | PMC |
http://dx.doi.org/10.1016/j.rboe.2012.11.001 | DOI Listing |
Sensors (Basel)
December 2024
Faculty of Computer Science, Kazimierz Wielki University, Chodkiewicza 30, 85-064 Bydgoszcz, Poland.
This paper presents the results of a study on the effect of moisture content in polylactic acid (PLA) filaments on dust emissions during incremental manufacturing. The tests were conducted in a customised chamber using a standard 3D printer, and Plantower PMS3003 sensors were used to monitor air quality by measuring PM1, PM2.5 and PM10 concentrations.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
School of Science, Harbin Institute of Technology, Shenzhen 518055, China.
As a category of polymeric materials, soft dielectrics, such as most elastomers and rubber-like materials, have shown great potential for extensive applications in various fields. Owing to their intriguing electromechanical coupling behaviors, the morphological instabilities in soft dielectrics have been an active research field in recent years. In this work, the recent progress in experimental and theoretical research on their electromechanical morphological instabilities is reviewed, especially regarding the theoretical aspect.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
OMV Exploration & Production GmbH, 1020 Vienna, Austria.
We focus on optimizing oil displacement in brownfields using alkali polymers (AP) flooding. The goal is to enhance rock-fluid and fluid-fluid interactions to improve oil recovery. The evaluation includes detailed screening of AP mixtures to ensure cost-effectiveness and maximize chemical slug efficiency, using an AP pilot project in Austria as a case study.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
College of Energy and Mining Engineering, Shandong University of Science and Technology, Qingdao 266590, China.
The shear failure of rock masses is one of the primary causes of underground engineering instability. The shear mechanical behavior of rocks at different sizes is of great significance for studying the shear failure pattern of engineering rock masses. However, due to the presence of various joints and defects in natural rocks, the obtained rock specimens exhibit significant discreteness, making it difficult to customize specimen sizes for size effect studies.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Ningbo Institute of Technology, Beihang University, Ningbo 315800, China.
The manufacturing precision of electro-hydraulic servo valve sleeves is critical to the performance and longevity of the valves. To ensure the service life of these valves, the valve sleeve is typically made from high-hardness martensitic stainless steel, which is considered a hard-to-cut material. Current honing methods often suffer from inefficiency and instability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!