A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determining dose enhancement factors of high-Z nanoparticles from simulations where lateral secondary particle disequilibrium exists. | LitMetric

Determining dose enhancement factors of high-Z nanoparticles from simulations where lateral secondary particle disequilibrium exists.

Phys Med Biol

Physikalisch-Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany. Author to whom any correspondence should be addressed.

Published: August 2019

Nanoparticles (NPs) containing high atomic number (high-Z) materials have been shown to enhance the radiobiological effectiveness of ionizing radiation. This effect is often attributed to an enhancement of the absorbed dose in the vicinity of the NPs, based on Monte Carlo simulations that show a significant local enhancement of the energy deposition on the microscopic scale. The results of such simulations may be significantly biased and lead to a severe overestimation of the dose enhancement if the condition of secondary particle equilibrium is not met in the simulation setup. This current work shows an approach to estimate a 'realistic' dose enhancement from the results of such biased simulations which is based on published photon interaction data and provides a way for correcting biased results.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab31d4DOI Listing

Publication Analysis

Top Keywords

dose enhancement
12
secondary particle
8
enhancement
5
determining dose
4
enhancement factors
4
factors high-z
4
high-z nanoparticles
4
simulations
4
nanoparticles simulations
4
simulations lateral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!