Between 1975 and 1983, 305 Hancock bioprostheses were implanted at the La Pitié Hospital, Paris, including 133 on the aortic valve and 172 on the mitral valve. The operative mortality rate was 6 p. 100 in patients with isolated aortic valve replacement and 12.8 p. 100 in patients with isolated mitral valve replacement (including 4 reoperations for mechanical valve thrombosis). 245 patients were followed up for a mean period of 5 1/2 years. The actuarial survival rate, operative mortality excluded, was 77.5 +/- 4.4 p. 100 in the aortic valve group and 76 +/- 4.4 p. 100 in the mitral valve group (non significant difference). Later after surgery, 8 embolic accidents (5 in the mitral valve group, 3 in the aortic valve group) occurred, and 20 patients developed endocarditis. Forty-nine patients required reoperation, 33 of them for deterioration of the bioprosthesis. The probability of being free from such deterioration varied significantly according to the patient's age at the time of the operation. In the aortic valve group this probability at 8 years was 97 p. 100 +/- 2.7 p. 100 for patients over 35 and 63.3 p. 100 +/- 1.7 p. 100 for patients under 35; the corresponding figures at 8 years in the mitral valve group were 80 p. 100 +/- 3.8 p. 100 for patients over 35 and 55.2 p. 100 +/- 2.2 p. 100 for patients under 35. There was no significant difference between the mitral and the aortic valve groups with regard to the percentage of prosthetic valve deterioration. The operative mortality rate in reoperations was 14.2 p. 100 irrespective of the cause of death.

Download full-text PDF

Source

Publication Analysis

Top Keywords

aortic valve
24
100 patients
24
+/- 100
24
valve group
24
mitral valve
20
100 +/-
16
valve
13
0
13
operative mortality
12
patients
10

Similar Publications

Background: Conduction disturbances are common after transcatheter aortic valve implantation (TAVI) and frequently require permanent pacemaker implantation (PPI). Data regarding its impact on mortality and morbidity are conflicting. This study aims to assess the impact of PPI before or within 30 days after TAVI on mortality and health-related Quality of Life (QoL) during the first year after TAVI.

View Article and Find Full Text PDF

A 70-year-old man developed intermittent fever with chills, severe anorexia, generalized weakness, and mild exertional difficulty in breathing following posterior chamber intraocular lens replacement surgery for a mature white cataract in the left eye. Laboratory tests revealed persistent negative blood cultures, normocytic and normochromic anemia, neutrophilia, and elevated inflammatory markers despite multiple courses of antibiotics. All other investigations conducted to identify the cause of prolonged fever, including transthoracic echocardiography, were negative.

View Article and Find Full Text PDF

Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!