A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In response to "Is solute movement within the extracellular spaces of brain gray matter brought about primarily by diffusion or flow?". | LitMetric

In our work, "Analysis of Convective and Diffusive Transport in the Brain Interstitium", published in this journal (2019, 16:6), we estimate the interstitial superficial velocity by comparison of transport model simulations to published experimental Real-Time Iontophoresis (RTI) data. In the Discussion section, we calculate a value for perfusion rate, or volumetric flow rate per unit mass of tissue, from these fundamental results of superficial velocity. Drs. Hladky and Barrand have proposed an alternative method for choosing the surface area per volume used to calculate perfusion rate from superficial velocity, using our model domain. Their method seems reasonable to us, as does ours. Upon reflection, a range of volumetric flow per unit mass values should have been reported in our paper, 1-40 μL/min-g. The value calculated using Drs. Hladky and Barrand surface area is a likely upper-bound on this range and the value in the paper is a low estimate at the bottom of the range. We are confident in the estimates of interstitial velocity reported in our article, using the assumptions of the model. Peclet (Pe) numbers, which compare convective and diffusive transport rates for different molecules, were calculated using the superficial velocity estimates; and we continue to believe these values are correct along with all other major results and conclusions presented in the paper.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6626393PMC
http://dx.doi.org/10.1186/s12987-019-0143-8DOI Listing

Publication Analysis

Top Keywords

superficial velocity
16
convective diffusive
8
diffusive transport
8
calculate perfusion
8
perfusion rate
8
volumetric flow
8
unit mass
8
drs hladky
8
hladky barrand
8
surface area
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!