Intravitreal injections and implants are used to deliver drugs to the retina because therapeutic levels of these medications cannot be provided by topical administration (i.e. eye drops). In order to reach the retina, a topically applied drug encounters tear dilution, reflex blinking, and rapid fluid drainage that collectively reduce the drug's residence time on the ocular surface. Residing under the tears, the cornea is the primary gateway into the eye for many topical ophthalmic drugs. We hypothesized that a drug-eluting contact lens that rests on the cornea would therefore be well-suited for delivering drugs to the eye including the retina. We developed a contact lens based dexamethasone delivery system (Dex-DS) that achieved sustained drug delivery to the retina at therapeutic levels. Dex-DS consists of a dexamethasone-polymer film encapsulated inside a contact lens. Rabbits wearing Dex-DS achieved retinal drug concentrations that were 200 times greater than those from intensive (hourly) dexamethasone drops. Conversely, Dex-DS demonstrated lower systemic (blood serum) dexamethasone concentrations. In an efficacy study in rabbits, Dex-DS successfully inhibited retinal vascular leakage induced by intravitreal injection of vascular endothelial growth factor (VEGF). Dex-DS was found to be safe in a four-week repeated dose biocompatibility study in healthy rabbits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.biomaterials.2019.119285 | DOI Listing |
Clin Exp Optom
January 2025
Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.
Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.
Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.
Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.
J Control Release
January 2025
Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health), Cixi Biomedical Research Institute, School of Pharmaceutical Sciences, Wenzhou Medical University, Ningbo, China. Electronic address:
Severe corneal injuries can cause visual impairment even blindness. Surgically stitching or implanting biomaterials have been developed, but their implementation requires professional surgeons, failing to address the immediate need of medical treatment. The pressing challenge lies in developing multifunctional biomaterials that enable self-management of corneal injuries.
View Article and Find Full Text PDFCont Lens Anterior Eye
January 2025
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China. Electronic address:
Purpose: To develop a Chinese version of the 8-item Contact Lens Dry Eye Questionnaire (CLDEQ-8) with cross-cultural adaption and clinical validation among soft contact lens wearers (SCL) in China.
Methods: The translation and adaptation of the Chinese CLDEQ-8 (C-CLDEQ-8) followed a rigorous methodological process based on cross-cultural research guidelines consisting of three main phases: 1) forward and backward translation of original CLDEQ-8 into Chinese, 2) cross-cultural adaptation performed by medical advising committee, and 3) clinical validation and repeatability test of the translated questionnaire on Chinese SCL wearers. Rasch analysis was also performed to investigate the psychometric properties of C-CLDEQ-8.
Am J Ophthalmol
January 2025
Department of Ophthalmology, University of Warmia and Mazury, Olsztyn, Poland; Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan Poland. Electronic address:
Purpose: Treatment of myopia has been informed by more than 3 decades of clinical trials and other observations. However, controversies regarding myopia control remain, such as when to stop treatment and what is the long-term efficacy of treatment. This perspective aims to describe clinically relevant and current controversies regarding myopia treatment.
View Article and Find Full Text PDFOphthalmic Physiol Opt
January 2025
Elite School of Optometry, Medical Research Foundation, Chennai, India.
Purpose: To investigate changes in fluid reservoir turbidity parameters over time and its influence on visual performance in eyes with ocular surface disorders (OSD) wearing scleral contact lenses (SL).
Methods: Thirteen eyes with OSD were assessed for corrected distance visual acuity, contrast sensitivity (CS) and fluid reservoir turbidity using anterior segment optical coherence tomography at baseline, after 5 min and 0.5, 1, 2, 3 and 4 h of SL wear on day 1 and after 1 month.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!