Urine protein detection by dipstick: No interference from alkalinity or specific gravity.

Clin Biochem

Department of Pathology and Laboratory Medicine, Cumming School of Medicine, Health Sciences Centre, Foothills Campus, University of Calgary, 3030 Hospital Drive NW, Calgary, AB T2N 4N1, Canada; Alberta Public Laboratories, Foothills Medical Centre, McCaig Tower, Rm 7507, 7(th) Floor, 3134 Hospital Drive NW, Calgary, AB T2N 5A1, Canada. Electronic address:

Published: September 2019

Tetrabromphenol blue dye based methods are used to detect proteinuria using urinalysis dipsticks. Manufacturers have claimed that alkalinity leads to false positive proteinuria, and that high specific gravity leads to false negative protein results. However, published reports describing this phenomenon remain equivocal. This study aimed to determine whether pH and/or specific gravity affect protein detection in patient urine using three different tetrabromophenol blue dye-based dipsticks. Patient urine pools were divided into individual aliquots with varied pH or specific gravity, and measured for protein in triplicate using iChem 10SG, iChem Velocity, and Multistix 8SG dipsticks. The pH experiment involved progressive alkalinization of urine aliquots with either 1M NaOH, NaCO, or NaHCO; pH was recorded by electrode. The specific gravity experiment involved mixing aliquots with NaCl and spiking with human albumin. Urine electrolytes and total CO were measured (Roche cobas 8000). Fresh patient urines (N = 35) were analyzed for physiological urine pH and total CO. Urine protein results were not affected by NaOH alkalinization up to pH 10.9. False positive protein occurred at pH 9.9 and >97 mmol/L total CO (NaCO alkalization; P < .05). Moreover, false positive protein occurred at pH 7.6 when total CO exceeded 137 mmol/L (NaHCO alkalization; P < .05). Fresh patient urines did not exceed pH 8.5 or 86 mmol/L total CO. NaCl elevated specific gravity and caused false negative protein detection when urine ionic strength was >1100 mmol/L (P < .05). Tetrabromphenol blue dipsticks provide robust detection of proteinuria when human urine is within physiological pH, total CO and ionic strength.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiochem.2019.07.005DOI Listing

Publication Analysis

Top Keywords

specific gravity
20
urine protein
8
protein detection
8
leads false
8
false positive
8
patient urine
8
experiment involved
8
urine
7
specific
5
gravity
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!